{"title":"Empire Vent-Free Gas Heaters","description":"\u003cp\u003eEmpire vent-free gas heaters at Hearth Depot. Check the vent-free sales policy for your state before ordering.\u003c\/p\u003e","products":[{"product_id":"empire-hearthrite-27-manual-25-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 27\" Manual 25,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 27\" Manual 25,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 25,000 BTU per hour on propane, a manual HI \/ LO control knob, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW25ML is the manual-control propane version of the 27 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25,000 BTU vent-free radiant heat:\u003c\/strong\u003e propane; the heater is equipped for one gas and is not field-convertible; HI \/ LO manual control knob; hold the knob 30 seconds after the pilot lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW25ML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003ePropane - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, HI \/ LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003ePropane 11 to 14 in w.c. inlet (100 lb minimum tank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 27.16 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e25.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; propane 11 to 14 in w.c. inlet, from a tank of at least 100 lb capacity; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085577455,"sku":"HRW25ML","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW25ML_4ee1a389-3c97-4ee0-a1d0-13c2606e48d0.jpg?v=1784547570"},{"product_id":"empire-hearthrite-27-thermostat-25-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 27\" Thermostat 25,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 27\" Thermostat 25,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 25,000 BTU per hour on propane, a thermostat that cycles the burner to hold the room temperature, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW25TL is the thermostat propane version of the 27 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25,000 BTU vent-free radiant heat:\u003c\/strong\u003e propane; the heater is equipped for one gas and is not field-convertible; thermostat heat control cycles the burner to the room temperature you set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW25TL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003ePropane - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eThermostat heat control (cycles the burner to the set room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003ePropane 11 to 14 in w.c. inlet (100 lb minimum tank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 27.16 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e25.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; propane 11 to 14 in w.c. inlet, from a tank of at least 100 lb capacity; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085675759,"sku":"HRW25TL","price":635.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW25ML_66fdffef-9760-4a05-9eb5-2ddf4e74f148.jpg?v=1784547575"},{"product_id":"empire-hearthrite-20-manual-18-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 20\" Manual 18,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 20\" Manual 18,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 18,000 BTU per hour on natural gas, a manual HI \/ LO control knob, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW18MN is the manual-control natural gas version of the 20 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas; the heater is equipped for one gas and is not field-convertible; HI \/ LO manual control knob; hold the knob 30 seconds after the pilot lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW18MN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, HI \/ LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas 7 to 10.5 in w.c. inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 19.84 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18.30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; natural gas 7 to 10.5 in w.c. inlet; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085741295,"sku":"HRW18MN","price":415.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW18TN_5d8a023c-25b7-427f-b3e7-01452c6993be.jpg?v=1784547580"},{"product_id":"empire-hearthrite-20-thermostat-18-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 20\" Thermostat 18,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 20\" Thermostat 18,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 18,000 BTU per hour on natural gas, a thermostat that cycles the burner to hold the room temperature, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW18TN is the thermostat natural gas version of the 20 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas; the heater is equipped for one gas and is not field-convertible; thermostat heat control cycles the burner to the room temperature you set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW18TN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eThermostat heat control (cycles the burner to the set room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas 7 to 10.5 in w.c. inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 19.84 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18.30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; natural gas 7 to 10.5 in w.c. inlet; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085806831,"sku":"HRW18TN","price":545.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW18TN_c9888847-291a-48c6-bb94-4f741ba2805b.jpg?v=1784547585"},{"product_id":"empire-hearthrite-27-manual-30-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 27\" Manual 30,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 27\" Manual 30,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 30,000 BTU per hour on natural gas, a manual HI \/ LO control knob, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW30MN is the manual-control natural gas version of the 27 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas; the heater is equipped for one gas and is not field-convertible; HI \/ LO manual control knob; hold the knob 30 seconds after the pilot lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW30MN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, HI \/ LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas 7 to 10.5 in w.c. inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 27.16 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e25.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; natural gas 7 to 10.5 in w.c. inlet; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085905135,"sku":"HRW30MN","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW25ML_6e126c10-4001-44a5-9523-545f87f820f6.jpg?v=1784547589"},{"product_id":"empire-hearthrite-27-thermostat-30-000-btu-vent-free-infrared-heater","title":"Empire HearthRite 27\" Thermostat 30,000 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 27\" Thermostat 30,000 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 30,500 BTU per hour on natural gas, a thermostat that cycles the burner to hold the room temperature, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW30TN is the thermostat natural gas version of the 27 in HearthRite radiant heater (the brochure rates it 30,500 BTU; the listing title says 30,000). It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,500 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas; the heater is equipped for one gas and is not field-convertible; thermostat heat control cycles the burner to the room temperature you set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW30TN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e30,500 BTU\/h (brochure; the listing title says 30,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eThermostat heat control (cycles the burner to the set room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas 7 to 10.5 in w.c. inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 27.16 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e25.57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; natural gas 7 to 10.5 in w.c. inlet; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213085970671,"sku":"HRW30TN","price":635.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW25ML_a9b4a9f8-a017-426d-bd67-c65dabacef1f.jpg?v=1784547593"},{"product_id":"empire-hearthrite-20-thermostat-20-000-btu-vent-free-blueflame-heater","title":"Empire HearthRite 20\" Thermostat 20,000 BTU Vent-Free BlueFlame Heater","description":"\u003cp\u003eThe Empire HearthRite 20\" Thermostat 20,000 BTU Vent-Free BlueFlame Heater is a HearthRite vent-free blue flame wall heater: 20,000 BTU per hour on propane (HBW20TL) or natural gas (HBW20TN) as ordered, a thermostat that cycles the burner to hold the room temperature, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Blue flame heaters warm the room air behind a viewing glass with its barrier.\u003c\/p\u003e\u003cp\u003eTwo models in one listing: HBW20TN natural gas and HBW20TL propane; both thermostat-controlled. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Thermostat and manual versions are listed separately.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20,000 BTU vent-free blue flame heat:\u003c\/strong\u003e propane (HBW20TL) or natural gas (HBW20TN) as ordered; the heater is equipped for one gas and is not field-convertible; thermostat heat control cycles the burner to the room temperature you set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHBW20TN \/ HBW20TL (natural gas \/ propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free blue flame wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003ePropane (HBW20TL) or natural gas (HBW20TN) as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eThermostat heat control (cycles the burner to the set room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas 7 to 10.5 in w.c. \/ propane 11 to 14 in w.c. inlet (100 lb minimum tank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 19.84 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18.90 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; natural gas 7 to 10.5 in w.c. or propane 11 to 14 in w.c. inlet (100 lb minimum tank); never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905VFIR-2 (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213086068975,"sku":"HBW20TN","price":525.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213086101743,"sku":"HBW20TL","price":449.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HBW20MN_547e3f94-0cbd-485f-83fd-7c89c41595ae.jpg?v=1784547599"},{"product_id":"empire-12-manual-1-heat-setting-white-6-000-btu-vent-free-infrared-heater","title":"Empire 12\" Manual 1-Heat Setting White 6,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 12\" Manual 1-Heat Setting White 6,000 Btu, Vent-Free Infrared Heater is Empire's 12 in white vent-free infrared (radiant) room heater: 6,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), a single-setting manual control knob, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR6WNAT for natural gas and SR6WLP for propane - the manual's SR-6W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e, takes no blower (Empire lists none for the 12 in heaters), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. At 6,000 BTU it is the one model in the line allowed in a bathroom or bedroom - wall mounted, in an unconfined space. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR6WNAT) or propane (SR6WLP), fixed at purchase; one heat setting - the manual knob runs the single plaque at full input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual knob that locks into each setting:\u003c\/strong\u003e slightly depress and turn the knob to the heat position; it must lock into the setting - a knob left between positions causes incomplete combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e is the optional way to put it on the floor (not in a bedroom or bathroom).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo blower:\u003c\/strong\u003e Empire lists no blower for the 12 in heaters - the single plaque radiates its heat directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR6WNAT (natural gas) \/ SR6WLP (propane) - SR-6W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e6,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, one heat setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 7\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6 in each side; 0 in rear; 24 in to the ceiling; 10 in below a shelf or sill (shelf extension 12 in maximum); 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 300 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS10W floor stand (bathroom and bedroom installations wall-mounted only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRS10W floor stand; no blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; mobile-home approved; bathroom \/ bedroom use wall-mounted in an unconfined space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS10W floor stand (sold with its own four screws)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall position in a room of at least 300 cu ft; as a 6,000 BTU heater it may be installed in a bathroom or bedroom when wall mounted in an unconfined space; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 6 in to each side wall, 0 in to the rear wall, 24 in to the ceiling, 10 in below any shelf or window sill that projects no more than 12 in, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (300 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then depress and turn to the heat setting until it locks. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39910-1-0919 (09\/2019, the family manual that lists SR-6W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086331119,"sku":"SR6WLP","price":539.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213086363887,"sku":"SR6WNAT","price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR6WLP_a0d13f95-d61e-41a5-939c-93e703ce22f3.jpg?v=1784547610"},{"product_id":"empire-12-manual-1-heat-setting-white-10-000-btu-vent-free-infrared-heater","title":"Empire 12\" Manual 1-Heat Setting White 10,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 12\" Manual 1-Heat Setting White 10,000 Btu, Vent-Free Infrared Heater is Empire's 12 in white vent-free infrared (radiant) room heater: 10,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), a single-setting manual control knob, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR10WNAT for natural gas and SR10WLP for propane - the manual's SR-10W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e, takes no blower (Empire lists none for the 12 in heaters), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. At 10,000 BTU it may go in a bedroom (wall mounted, unconfined space) but not in a bathroom. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR10WNAT) or propane (SR10WLP), fixed at purchase; one heat setting - the manual knob runs the single plaque at full input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual knob that locks into each setting:\u003c\/strong\u003e slightly depress and turn the knob to the heat position; it must lock into the setting - a knob left between positions causes incomplete combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e is the optional way to put it on the floor (never in a bedroom).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo blower:\u003c\/strong\u003e Empire lists no blower for the 12 in heaters - the single plaque radiates its heat directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR10WNAT (natural gas) \/ SR10WLP (propane) - SR-10W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, one heat setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 7\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6 in each side; 0 in rear; 24 in to the ceiling; 14 in below a shelf or sill (shelf extension 12 in maximum); 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS10W floor stand (bedroom installations wall-mounted only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRS10W floor stand; no blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; mobile-home approved; bedroom use wall-mounted in an unconfined space, not for bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS10W floor stand (sold with its own four screws)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 500 cu ft; as a 10,000 BTU heater it may be installed in a bedroom (wall mounted, unconfined space) but never in a bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 6 in to each side wall, 0 in to the rear wall, 24 in to the ceiling, 14 in below any shelf or window sill that projects no more than 12 in, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then depress and turn to the heat setting until it locks. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39910-1-0919 (09\/2019, the family manual that lists SR-10W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086527727,"sku":"SR10WLP","price":539.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213086560495,"sku":"SR10WNAT","price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR6WLP_82303203-6c76-42f2-a79b-0f9a29f2828d.jpg?v=1784547615"},{"product_id":"empire-12-hydraulic-thermostat-white-10-000-btu-vent-free-infrared-heater","title":"Empire 12\" Hydraulic Thermostat, White 10,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 12\" Hydraulic Thermostat, White 10,000 Btu, Vent-Free Infrared Heater is Empire's 12 in white vent-free infrared (radiant) room heater: 10,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), hydraulic thermostat that cycles the burner on at the full 10,000 BTU per hour and off again, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR10TWNAT for natural gas and SR10TWLP for propane - the manual's SR-10TW-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e, takes no blower (Empire lists none for the 12 in heaters), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. At 10,000 BTU it may go in a bedroom (wall mounted, unconfined space) but not in a bathroom. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR10TWNAT) or propane (SR10TWLP), fixed at purchase; the hydraulic thermostat cycles the burner on at full input and off when the room is satisfied; it does not modulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e is the optional way to put it on the floor (never in a bedroom).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo blower:\u003c\/strong\u003e Empire lists no blower for the 12 in heaters - the single plaque radiates its heat directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR10TWNAT (natural gas) \/ SR10TWLP (propane) - SR-10TW-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eHydraulic thermostat (cycles on \/ off at full input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 7\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6 in each side; 0 in rear; 24 in to the ceiling; 14 in below a shelf or sill (shelf extension 12 in maximum); 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS10W floor stand (bedroom installations wall-mounted only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRS10W floor stand; no blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2019 unvented room heater, CSA; mobile-home approved; bedroom use wall-mounted in an unconfined space, not for bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS10W floor stand (sold with its own four screws)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 500 cu ft; as a 10,000 BTU heater it may be installed in a bedroom (wall mounted, unconfined space) but never in a bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 6 in to each side wall, 0 in to the rear wall, 24 in to the ceiling, 14 in below any shelf or window sill that projects no more than 12 in, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS10W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39909-3-1124 (11\/2024, the family manual that lists SR-10TW-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086626031,"sku":"SR10TWLP","price":679.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213086658799,"sku":"SR10TWNAT","price":679.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR6WLP_77028c00-472d-45fb-9cd3-49fe54298bd7.jpg?v=1784547620"},{"product_id":"empire-18-hydraulic-thermostat-white-18-000-btu-vent-free-infrared-heater","title":"Empire 18\" Hydraulic Thermostat, White 18,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 18\" Hydraulic Thermostat, White 18,000 Btu, Vent-Free Infrared Heater is Empire's 18 in white vent-free infrared (radiant) room heater: 18,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), hydraulic thermostat that cycles the burner on at the full 18,000 BTU per hour and off again, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR18TWNAT for natural gas and SR18TWLP for propane - the manual's SR-18TW-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB18W manual blower for this size), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR18TWNAT) or propane (SR18TWLP), fixed at purchase; the hydraulic thermostat cycles the burner on at full input and off when the room is satisfied; it does not modulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB18W manual blower for this size) fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR18TWNAT (natural gas) \/ SR18TWLP (propane) - SR-18TW-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eHydraulic thermostat (cycles on \/ off at full input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 900 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB18TW blower (manual); brochure also lists the SRB18W; SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2019 unvented room heater, CSA; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS18W floor stand (sold with its own four screws), the SRB18TW blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 900 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 6 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (900 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB18W manual blower for this size): the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39909-3-1124 (11\/2024, the family manual that lists SR-18TW-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086757103,"sku":"SR18TWLP","price":835.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213086789871,"sku":"SR18TWNAT","price":835.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR18TWLP_3cfc3f26-dfb2-496d-b1b4-9ad18887a098.jpg?v=1784547626"},{"product_id":"empire-24-hydraulic-thermostat-white-30-000-btu-vent-free-infrared-heater","title":"Empire 24\" Hydraulic Thermostat, White 30,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 24\" Hydraulic Thermostat, White 30,000 Btu, Vent-Free Infrared Heater is Empire's 24 in white vent-free infrared (radiant) room heater: 30,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), hydraulic thermostat that cycles the burner on at the full 30,000 BTU per hour and off again, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR30TWNAT for natural gas and SR30TWLP for propane - the manual's SR-30TW-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB30W manual blower for this size), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR30TWNAT) or propane (SR30TWLP), fixed at purchase; the hydraulic thermostat cycles the burner on at full input and off when the room is satisfied; it does not modulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB30W manual blower for this size) fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR30TWNAT (natural gas) \/ SR30TWLP (propane) - SR-30TW-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eHydraulic thermostat (cycles on \/ off at full input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 1\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e8 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 1,500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB30TW blower (manual); brochure also lists the SRB30W; SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2019 unvented room heater, CSA; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS30W floor stand (sold with its own four screws), the SRB30TW blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 1,500 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 8 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (1,500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e (the brochure also lists the SRB30W manual blower for this size): the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39909-3-1124 (11\/2024, the family manual that lists SR-30TW-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086888175,"sku":"SR30TWLP","price":1089.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213086920943,"sku":"SR30TWNAT","price":1089.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR30TWLP_9772d321-65b7-493b-8c00-6d150e068ed4.jpg?v=1784547631"},{"product_id":"empire-18-manual-3-heat-settings-white-18-000-btu-vent-free-infrared-heater","title":"Empire 18\" Manual 3-Heat Settings, White 18,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 18\" Manual 3-Heat Settings, White 18,000 Btu, Vent-Free Infrared Heater is Empire's 18 in white vent-free infrared (radiant) room heater: 18,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), a three-setting manual control knob, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR18WNAT for natural gas and SR18WLP for propane - the manual's SR-18W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18W manual blower\u003c\/a\u003e (the brochure also lists the SRB18TW automatic blower for this size), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR18WNAT) or propane (SR18WLP), fixed at purchase; three heat settings: one plaque 6,700, two plaques 12,000, three plaques 18,000 BTU per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual knob that locks into each setting:\u003c\/strong\u003e slightly depress and turn the knob to the heat position; it must lock into the setting - a knob left between positions causes incomplete combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18W manual blower\u003c\/a\u003e (the brochure also lists the SRB18TW automatic blower for this size) fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR18WNAT (natural gas) \/ SR18WLP (propane) - SR-18W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU\/h at setting 3 (6,700 \/ 12,000 \/ 18,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, three heat settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 900 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB18W blower (manual); brochure also lists the SRB18TW; SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS18W floor stand (sold with its own four screws), the SRB18W blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 900 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 6 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (900 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18W manual blower\u003c\/a\u003e (the brochure also lists the SRB18TW automatic blower for this size): the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then depress and turn to the heat setting until it locks. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39910-1-0919 (09\/2019, the family manual that lists SR-18W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213086986479,"sku":"SR18WLP","price":669.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213087019247,"sku":"SR18WNAT","price":669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR18TWLP_e8c57d70-d827-4d23-98ac-8d7e9f73e95a.jpg?v=1784547636"},{"product_id":"empire-24-manual-3-heat-settings-white-30-000-btu-vent-free-infrared-heater","title":"Empire 24\" Manual 3-Heat Settings, White 30,000 Btu, Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire 24\" Manual 3-Heat Settings, White 30,000 Btu, Vent-Free Infrared Heater is Empire's 24 in white vent-free infrared (radiant) room heater: 30,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), a three-setting manual control knob, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. The ceramic plaques glow red-orange and radiate heat straight to you and the objects in the room, the way sunlight warms through a window.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: SR30WNAT for natural gas and SR30WLP for propane - the manual's SR-30W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30W manual blower\u003c\/a\u003e (the brochure also lists the SRB30TW automatic blower for this size), and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU vent-free radiant heat:\u003c\/strong\u003e natural gas (SR30WNAT) or propane (SR30WLP), fixed at purchase; three heat settings: one plaque 8,000 BTU per hour on natural gas or 7,000 on propane, three plaques 18,000, five plaques 30,000 BTU per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual knob that locks into each setting:\u003c\/strong\u003e slightly depress and turn the knob to the heat position; it must lock into the setting - a knob left between positions causes incomplete combustion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30W manual blower\u003c\/a\u003e (the brochure also lists the SRB30TW automatic blower for this size) fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSR30WNAT (natural gas) \/ SR30WLP (propane) - SR-30W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free infrared (radiant) ceramic plaque wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h at setting 3 (8,000 natural or 7,000 propane \/ 18,000 \/ 30,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, three heat settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 1\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 7.0 to 10.5 in w.c. (manifold about 6.0 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e8 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 1,500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB30W blower (manual); brochure also lists the SRB30TW; SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS30W floor stand (sold with its own four screws), the SRB30W blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 1,500 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 8 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (1,500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 7.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30W manual blower\u003c\/a\u003e (the brochure also lists the SRB30TW automatic blower for this size): the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then depress and turn to the heat setting until it locks. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39910-1-0919 (09\/2019, the family manual that lists SR-30W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213087150319,"sku":"SR30WLP","price":855.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213087183087,"sku":"SR30WNAT","price":855.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_SR30TWLP_a692c0d4-38fb-4fe4-9fa7-ac806b5ec1f8.jpg?v=1784547641"},{"product_id":"empire-18-modulating-hydraulic-thermostat-white-10-000-btu-vent-free-blueflame-heater","title":"Empire 18\" Modulating Hydraulic Thermostat, White 10,000 BTU Vent-Free BlueFlame Heater","description":"\u003cp\u003eThe Empire 18\" Modulating Hydraulic Thermostat, White 10,000 BTU Vent-Free BlueFlame Heater is Empire's 18 in white vent-free blue flame room heater: 10,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), hydraulic thermostat with a constant 10,000 BTU per hour input, a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. Blue flame heaters warm the room air, which then surrounds people and objects with even warmth.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: BF10WNAT for natural gas and BF10WLP for propane - the manual's BF-10W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e, and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. At 10,000 BTU it may go in a bedroom (wall mounted, unconfined space) but not in a bathroom. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free BlueFlame Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU vent-free blue flame heat:\u003c\/strong\u003e natural gas (BF10WNAT) or propane (BF10WLP), fixed at purchase; the hydraulic thermostat cycles the burner at its constant 10,000 BTU input (this model does not modulate).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e is the optional way to put it on the floor (never in a bedroom).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eBF10WNAT (natural gas) \/ BF10WLP (propane) - BF-10W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free blue flame wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eHydraulic thermostat, constant input (non-modulating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 5.0 to 10.5 in w.c. (manifold about 3.5 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e5 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS18W floor stand (bedroom installations wall-mounted only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB18TW blower; SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; UL file no. MH46389; mobile-home approved; bedroom use wall-mounted in an unconfined space, not for bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS18W floor stand (sold with its own four screws), the SRB18TW blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 500 cu ft; as a 10,000 BTU heater it may be installed in a bedroom (wall mounted, unconfined space) but never in a bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 5 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 5.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e: the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39892-9-1124 (11\/2024, the family manual that lists BF-10W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213088067823,"sku":"BF10WNAT","price":709.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213088100591,"sku":"BF10WLP","price":709.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/BF10W_e8eab85b-a4ce-4671-890b-b2e186107fec.jpg?v=1784547663"},{"product_id":"empire-18-modulating-hydraulic-thermostat-white-20-000-btu-vent-free-blueflame-heater","title":"Empire 18\" Modulating Hydraulic Thermostat, White 20,000 BTU Vent-Free BlueFlame Heater","description":"\u003cp\u003eThe Empire 18\" Modulating Hydraulic Thermostat, White 20,000 BTU Vent-Free BlueFlame Heater is Empire's 18 in white vent-free blue flame room heater: 20,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), modulating hydraulic thermostat (8,500 to 20,000 BTU per hour), a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. Blue flame heaters warm the room air, which then surrounds people and objects with even warmth.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: BF20WNAT for natural gas and BF20WLP for propane - the manual's BF-20W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e, and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free BlueFlame Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e20,000 BTU vent-free blue flame heat:\u003c\/strong\u003e natural gas (BF20WNAT) or propane (BF20WLP), fixed at purchase; the modulating hydraulic thermostat runs the burner between 8,500 BTU per hour at LO and 20,000 BTU per hour at HI (the thermostat section of the manual rates the natural gas HI setting at 18,000).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eBF20WNAT (natural gas) \/ BF20WLP (propane) - BF-20W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free blue flame wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e20,000 BTU\/h at HI (the manual's thermostat section rates natural gas HI at 18,000 BTU\/h); modulates from 8,500 BTU\/h at LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eModulating hydraulic thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 5.0 to 10.5 in w.c. (manifold about 3.5 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e5 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 1,000 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB18TW blower; SRS18W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; UL file no. MH46389; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS18W floor stand (sold with its own four screws), the SRB18TW blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 1,000 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 5 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (1,000 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS18W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 5.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB18TW automatic blower\u003c\/a\u003e: the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39892-9-1124 (11\/2024, the family manual that lists BF-20W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213088362735,"sku":"BF20WNAT","price":749.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213088395503,"sku":"BF20WLP","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/BF20W_ce3e20fb-a896-4bb1-ad58-d0dc960ee735.jpg?v=1784547668"},{"product_id":"empire-24-modulating-hydraulic-thermostat-white-30-000-btu-vent-free-blueflame-heater","title":"Empire 24\" Modulating Hydraulic Thermostat, White 30,000 BTU Vent-Free BlueFlame Heater","description":"\u003cp\u003eThe Empire 24\" Modulating Hydraulic Thermostat, White 30,000 BTU Vent-Free BlueFlame Heater is Empire's 24 in white vent-free blue flame room heater: 30,000 BTU per hour on natural gas or propane (chosen when you order - the heater is built for one gas and is never converted), modulating hydraulic thermostat (8,500 to 30,000 BTU per hour), a standing pilot you light with the piezo button, and an Oxygen Depletion Sensor pilot. Nothing in it needs electricity, so it heats through a power outage and, being vent-free, keeps 99.9 percent of the fuel's heat in the room. Blue flame heaters warm the room air, which then surrounds people and objects with even warmth.\u003c\/p\u003e\u003cp\u003eTwo variants in one listing: BF30WNAT for natural gas and BF30WLP for propane - the manual's BF-30W-1. It hangs on the wall from four mounting screws or rests on the optional \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e, takes the \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e, and is design-certified to ANSI Z21.11.2 by CSA as an unvented room heater. Rated over 10,000 BTU, it is not a bedroom or bathroom heater. Supplemental heat for a room, never the primary heat for a house.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Vent-Free BlueFlame Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,000 BTU vent-free blue flame heat:\u003c\/strong\u003e natural gas (BF30WNAT) or propane (BF30WLP), fixed at purchase; the modulating hydraulic thermostat runs the burner between 8,500 BTU per hour at LO and 30,000 BTU per hour at HI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e standing pilot, piezo pushbutton igniter and a gas control that needs no power or batteries - heat through an outage, 99.9 percent of the fuel's heat kept in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensor pilot:\u003c\/strong\u003e the pilot light safety system shuts the heater off when the room runs short of fresh air; the heater is relit only after fresh air is provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat you set once:\u003c\/strong\u003e LO to HI covers roughly 55 F to 90 F at the thermostat bulb at the bottom of the casing (not the room temperature); turn the knob to PILOT when no heat is wanted, since at LO the burner still lights when the bulb drops to 55 F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or floor:\u003c\/strong\u003e four wall-mounting screws (and plastic anchors for sheet rock) come in the hardware package; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e is the optional way to put it on the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e fits behind the top louver and plugs into a grounded three-prong receptacle; the heater itself keeps running without it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Empire's limited lifetime parts warranty with five-year labor on the combustion chamber and heat exchanger, five-year parts and labor on all other components (except thermostats) and one-year parts on thermostats, accessories and parts - original purchaser, qualified installer, proof of purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 and local codes (Massachusetts: a licensed plumber or gas fitter, a flexible connector no longer than three feet, and unvented heaters are prohibited in bedrooms and bathrooms).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eBF30WNAT (natural gas) \/ BF30WLP (propane) - BF-30W-1 in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free blue flame wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h at HI; modulates from 8,500 BTU\/h at LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas or propane as ordered - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eModulating hydraulic thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo pushbutton igniter, ODS safety pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 1\/8 in W x 22 in H x 6 1\/2 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Inlet\u003c\/td\u003e\n\u003ctd\u003e3\/8 in NPT, in the bottom of the heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003eNatural gas inlet 5.0 to 10.5 in w.c. (manifold about 3.5 in w.c.); propane inlet 11.0 to 13.0 in w.c. (manifold about 10.0 in w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e8 in each side; 0 in rear; 36 in to the ceiling; 36 in below a shelf or sill; 2 in above the floor; never in an alcove or closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); an unconfined space of at least 1,500 cu ft (50 cu ft per 1,000 BTU\/h of all appliances in it) or combustion air per the National Fuel Gas Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run the heater; the optional blower plugs into a properly grounded three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall, on four mounting screws; or the optional SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSRB30TW blower; SRS30W floor stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e35 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2-2016 unvented room heater, CSA; UL file no. MH46389; mobile-home approved; not for bedrooms or bathrooms (over 10,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime parts + 5-year labor (combustion chamber, heat exchanger); 5-year parts and labor (other components, except thermostats); 1-year parts (thermostats, accessories, parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with its standing pilot, piezo igniter and gas control\u003c\/li\u003e\n\u003cli\u003eHardware package: four #10 x 1 in mounting screws and four plastic expansion anchors\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual, warranty card\u003c\/li\u003e\n\u003cli\u003eNot included: the SRS30W floor stand (sold with its own four screws), the SRB30TW blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor-stand position in a room of at least 1,500 cu ft; rated over 10,000 BTU per hour it is never installed in a bedroom or bathroom; Massachusetts prohibits unvented heaters in bedrooms and bathrooms; out of traffic and away from furniture and draperies; not in an alcove or closet; permitted in an aftermarket manufactured (mobile) home where codes allow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 8 in to each side wall, 0 in to the rear wall, 36 in to the ceiling, 36 in below any shelf or window sill, 2 in from the bottom of the heater to carpeting or tile, plus clearance around the air openings and for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e an unvented heater draws its air from the room: at least 50 cu ft of room volume per 1,000 BTU per hour of every appliance in it (1,500 cu ft for this heater alone), or two combustion-air openings sized per the National Fuel Gas Code; buildings of unusually tight construction need additional fresh air; expect about 1 oz of water vapor per 1,000 BTU of input per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e on a solid wall drive the four #10 x 1 in screws, leave a 1\/8 in gap under the heads and hang the heater on them; on sheet rock drill four 5\/16 in holes for the plastic expansion anchors; the lower louver, reflector and upper louver come off (two screws each) and go back with the louver lip behind and the reflector lip in front of the heat shield; the \u003ca href=\"\/products\/empire-stand-for-floor-vent-free-infrared-blueflame-heater-accessories\"\u003eSRS30W floor stand\u003c\/a\u003e attaches to the bottom of the heater with its four screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e 3\/8 in NPT inlet in the bottom of the heater; its own manual shut-off, union, drip-line sediment trap and a 1\/8 in NPT test tapping upstream; natural gas 5.0 to 10.5 in w.c. or propane 11.0 to 13.0 in w.c. inlet pressure; 1\/2 in pipe for runs to 100 ft on natural gas (3\/8 in propane to 10 ft); never plastic pipe or well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e above 2,000 ft reduce the rating 4 percent per 1,000 ft; the manufacturer or gas company rules on orifice changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e The \u003ca href=\"\/products\/empire-automatic-blower-vent-free-infrared-blueflame-heater-accessory\"\u003eSRB30TW automatic blower\u003c\/a\u003e: the heater comes off the wall (or stays on its floor stand) while the blower housing is fastened to the top heat shield with four screws and the cord set is led through the casing back; three-prong grounding plug into a properly grounded receptacle; unplugging the blower does not stop the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLighting and care:\u003c\/strong\u003e knob to OFF, wait 10 minutes, knob to PILOT, push in and press the piezo button until the pilot lights, hold about one minute, then counterclockwise to HI and set the thermostat; the gas control's interlock allows a relight about 60 seconds after a shut-off. Annual inspection and cleaning by the dealer before the heating season; no fans blowing at the heater, no scented candles or air fresheners while it runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the Empire installation instructions and owner's manual 39892-9-1124 (11\/2024, the family manual that lists BF-30W-1) and the Empire Heating Systems infrared and blue flame heaters brochure EHS-01032 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty service:\u003c\/strong\u003e warranty claims go through the installing dealer with the model number, serial number, type of gas and purchase verification; the dealer initiates warranted parts replacements, and parts after the warranty come through the dealer or a Master Parts Distributor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213088493807,"sku":"BF30WNAT","price":865.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213088526575,"sku":"BF30WLP","price":865.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/BF30W_91389dd7-7d29-42b2-8ddc-d452a1c3b46c.jpg?v=1784547674"},{"product_id":"empire-hearthrite-20-manual-16-800-btu-vent-free-infrared-heater","title":"Empire HearthRite 20\" Manual 16,800 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 20\" Manual 16,800 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 16,800 BTU per hour on propane, a manual HI \/ LO control knob, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW17ML is the manual-control propane version of the 20 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16,800 BTU vent-free radiant heat:\u003c\/strong\u003e propane; the heater is equipped for one gas and is not field-convertible; HI \/ LO manual control knob; hold the knob 30 seconds after the pilot lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW17ML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e16,800 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003ePropane - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual control knob, HI \/ LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003ePropane 11 to 14 in w.c. inlet (100 lb minimum tank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 19.84 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18.30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; propane 11 to 14 in w.c. inlet, from a tank of at least 100 lb capacity; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213161074927,"sku":"HRW17ML","price":415.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW18TN_95f42dfd-ed8b-4764-87df-bcca6232434f.jpg?v=1784549775"},{"product_id":"empire-hearthrite-20-thermostat-17-100-btu-vent-free-infrared-heater","title":"Empire HearthRite 20\" Thermostat 17,100 BTU Vent-Free Infrared Heater","description":"\u003cp\u003eThe Empire HearthRite 20\" Thermostat 17,100 BTU Vent-Free Infrared Heater is a HearthRite vent-free radiant (infrared) wall heater: 17,100 BTU per hour on propane, a thermostat that cycles the burner to hold the room temperature, a piezo igniter and an Oxygen Depletion Sensing pilot - no electricity, batteries or matches to run it, so it heats when the power fails and keeps 99.9 percent of the fuel's heat in the room. Radiant plaques warm people and objects in front of the heater.\u003c\/p\u003e\u003cp\u003eThe HRW17TL is the thermostat propane version of the 20 in HearthRite radiant heater. It mounts on the wall with the included bracket or stands on the included support legs, is certified to ANSI Z21.11.2 by CSA, and - rated over 10,000 BTU - is not installed in a bedroom or bathroom. Add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e to move the heat; Empire's HABF floor stand is sold separately. Use the selector to compare the manual and thermostat versions and the natural gas \/ propane ratings.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire HearthRite Vent-Free Infrared Heater family - use the selector above to compare the sizes and control options.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e17,100 BTU vent-free radiant heat:\u003c\/strong\u003e propane; the heater is equipped for one gas and is not field-convertible; thermostat heat control cycles the burner to the room temperature you set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuns without electricity:\u003c\/strong\u003e piezo igniter and standing pilot - heat through a power outage; 99.9 percent efficient, every BTU stays in the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOxygen Depletion Sensing pilot:\u003c\/strong\u003e shuts the heater off when fresh air runs short and cuts the gas on flame-out; pilot outage is possible above 4,500 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall bracket and legs included:\u003c\/strong\u003e mounting bracket, wall anchors, screws and spacers in the hardware package; two support legs and four screws for floor standing (not in a bedroom, bathroom or garage); the HABF floor stand is an accessory sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower-ready:\u003c\/strong\u003e the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR fan kit\u003c\/a\u003e mounts behind the rear knock-out panel (ON \/ OFF \/ Auto, three-prong 120 V plug).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e HearthRite's 3-year limited warranty on parts with limited labor, through a HearthRite authorized service center - original purchaser, bill of sale, qualified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e installation, gas piping and service by a qualified agency to the National Fuel Gas Code ANSI Z223.1 \/ NFPA 54 or CSA B149.1 and local codes, with permits and inspections (Massachusetts: a licensed plumber or gas fitter).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHRW17TL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eVent-free radiant (infrared) wall heater, supplemental heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e17,100 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003ePropane - not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eThermostat heat control (cycles the burner to the set room temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003ePiezo igniter, standing ODS pilot - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall-mounted on the included bracket, or floor-standing on the included support legs; HABF floor stand optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e36 in top to ceiling or shelf; 3 in bottom to carpet or tile; 36 in from furniture and draperies; 0 in rear to the wall spacer; second side wall 18 in; on carpet or tile other than wood flooring, on a metal or wood panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eNone - vent-free (unvented room heater); 50 cu ft of room volume per 1,000 BTU\/h or ventilation openings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Pressure\u003c\/td\u003e\n\u003ctd\u003ePropane 11 to 14 in w.c. inlet (100 lb minimum tank)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eNone to run; the optional HABLR fan kit plugs into a grounded 120 V, 60 Hz three-prong receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.11.2 vent-free room heater, CSA (MC 274387); mobile-home approved; not for bedrooms or bathrooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Size (brochure)\u003c\/td\u003e\n\u003ctd\u003e7.44 x 19.84 x 23 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight (brochure)\u003c\/td\u003e\n\u003ctd\u003e18.30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited parts with limited labor (HearthRite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHeater with the mounting bracket (taped to the back panel), wall anchors, mounting screws and spacers\u003c\/li\u003e\n\u003cli\u003eTwo support legs with four screws for floor standing\u003c\/li\u003e\n\u003cli\u003eUser's manual and operating instructions\u003c\/li\u003e\n\u003cli\u003eNot included: HABLR fan kit, HABF floor stand\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it may go:\u003c\/strong\u003e a wall or floor position in the coldest part of the room with easy access for operation and service; never in a bedroom or bathroom (over 10,000 BTU\/h), a recreational vehicle, a fireplace, a high-traffic, windy or drafty area, or where flammable liquids, vapors or dust are present; floor mounting is not done in a bedroom, bathroom or garage, and in a home garage the pilot and burner sit at least 18 in above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 36 in from the top of the heater to the ceiling, a shelf or other combustible, 3 in from the bottom to carpet or tile, 36 in from furniture, draperies and clothing on the front, top and sides, 0 in from the rear to the wall spacer, a second side wall at least 18 in away; on carpet or tile other than wood flooring the heater sits on a metal or wood panel the full width and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombustion and ventilation air:\u003c\/strong\u003e supplemental heat: 50 cu ft of space per 1,000 BTU\/h of every appliance drawing air from the room (the manual's worksheet), or ventilation to an adjoining room or outdoors; unusually tight construction needs additional fresh air; about 1 oz of water vapor per 1,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e wall: the bracket on studs or wall anchors with the heater locked by the bottom mounting screws; floor: the two support legs with four screws (select models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e its own equipment shut-off valve, union, plugged 1\/8 in NPT test tap and sediment trap; propane 11 to 14 in w.c. inlet, from a tank of at least 100 lb capacity; never on well-head gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan kit:\u003c\/strong\u003e to add the \u003ca href=\"\/products\/empire-hearthrite-blower-for-vent-free-infrared-blueflame-heaters\"\u003eHABLR blower\u003c\/a\u003e a qualified service person disconnects the heater from the gas supply, takes it off the wall, removes the rear knock-out panel and fastens the fan with its four screws; three-prong grounded 120 V, 60 Hz receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the HearthRite user's manual HR1905-3VFIR (07\/2019, the family manual that lists this model) and the HearthRite brochure 01046 are attached in the Documents tab.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService:\u003c\/strong\u003e warranty parts through HearthRite authorized dealers or HearthRite (800-851-3153) with the model and serial numbers; original factory replacement parts only.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Default Title","offer_id":50213161238767,"sku":"HRW17TL","price":545.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_HRW18TN_2aee97b0-b530-4418-85e6-1c291412ac26.jpg?v=1784549780"}],"url":"https:\/\/hearthdepot.com\/collections\/empire-vent-free-gas-heaters.oembed","provider":"Hearth Depot","version":"1.0","type":"link"}