{"title":"Empire Wall Furnaces","description":"\u003cp\u003eEmpire vented gas wall furnaces at Hearth Depot, in direct-vent and B-vent models.\u003c\/p\u003e","products":[{"product_id":"empire-16-dv210sgx-direct-vent-millivolt-wall-furnace-thermostat-not-included","title":"Empire 16\" DV210SGX Direct-Vent Millivolt Wall Furnace (Thermostat not included)","description":"\u003cp\u003eThe Empire 16\" DV210SGX Direct-Vent Millivolt Wall Furnace (Thermostat not included) is Empire's compact direct-vent wall furnace for a single room - a 10,000 BTU\/hr millivolt gas heater, 16 1\/4\" wide, that hangs on an inside wall plate against an outside wall and vents straight through it with the standard vent kit in the carton; natural gas or propane, no chimney and no electricity.\u003c\/p\u003e\u003cp\u003eSealed combustion draws its air from outside, the standing pilot lights with the push-button piezo, and the gas valve runs on its own thermopile, so the furnace keeps heating when the power is out. The wall thermostat is not included: it takes an optional on\/off device - the \u003ca href=\"\/products\/empire-wall-thermostat-reed-switch-control-option\"\u003eTMV millivolt wall thermostat\u003c\/a\u003e, a wall switch, toggle switch or remote - and the optional \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-dvb1\"\u003eDVB1 automatic blower\u003c\/a\u003e for more even heat.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Wall Furnace (DV210\/DV215) family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU\/hr direct vent:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a gravity direct vent wall furnace; combustion air in and flue gases out through one 6 1\/4\" wall opening; 65 to 66 percent AFUE per Empire's product guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats without electricity:\u003c\/strong\u003e standing pilot with piezo ignition and a millivolt valve; add the thermostat, wall switch or remote of your choice (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent kit included:\u003c\/strong\u003e inside and outside wall plates, 5\" air inlet tube, 3\" flue outlet tube and vent cap for walls 4 1\/2\" to 13\" deep; the \u003ca href=\"\/products\/empire-gas-furnace-flue-outlet-vent-tube-extension-kit\"\u003eTH345 flue outlet tube\u003c\/a\u003e and \u003ca href=\"\/products\/empire-gas-furnace-air-inlet-vent-tube-extension-kit\"\u003eTH346 air inlet tube\u003c\/a\u003e reach 19\" walls, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e (3\" deep) keeps the cap off vinyl siding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-dvb1\"\u003eDVB1 blower\u003c\/a\u003e (60 cu ft\/min), \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK1 vinyl siding kit, vent extension tubes and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDV210SGXNAT (natural gas), DV210SGXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e10,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e21 3\/8 x 16 1\/4 x 9 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 5 in air inlet tube, 3 in flue outlet tube; wall 4 1\/2 to 13 in (19 in with the extension tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e6 1\/4 in diameter minimum (plates cover up to 8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSides 1 in, top 12 in, floor 0 in; vent cap 16 in from an outside corner, 6 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 66 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent wall furnace\u003c\/li\u003e\n\u003cli\u003eComplete vent kit: inside wall plate, outside wall plate, 5\" air inlet tube, 3\" flue outlet tube, vent cap\u003c\/li\u003e\n\u003cli\u003eMounting hardware (#10 x 1 1\/2\" screws, Tinnerman nuts, toggle bolt, vent-cap screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: wall thermostat or other on\/off device, blower, vinyl siding kit, vent extension tubes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall between studs, hung on the inside wall plate over a 6 1\/4\" minimum opening; wall depth 4 1\/2\" to 13\" (to 19\" with the extension tubes); the vent is centered on the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 1\" at the sides, 12\" above, 0\" to the floor (2\" suggested for future floor coverings); outside, the vent cap sits at least 16\" from an outside corner or obstruction, 6\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the optional on\/off device wires to the two valve wires and sits 4 to 5 ft up an interior wall in the same room; the blower plugs into a grounded three-prong receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpet or tile:\u003c\/strong\u003e on a combustible floor covering other than wood the furnace sits on a metal or wood panel its full width and depth; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213089738991,"sku":"DV210SGXNAT","price":1329.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213089771759,"sku":"DV210SGXLP","price":1329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DV210-215_eb2b4d9a-674d-432f-ba7e-ae1d69c28af8.jpg?v=1784547723"},{"product_id":"empire-20-dv215sgx-direct-vent-millivolt-wall-furnace-thermostat-not-included","title":"Empire 20\" DV215SGX Direct-Vent Millivolt Wall Furnace (Thermostat not included)","description":"\u003cp\u003eThe Empire 20\" DV215SGX Direct-Vent Millivolt Wall Furnace (Thermostat not included) is Empire's compact direct-vent wall furnace for a single room - a 15,000 BTU\/hr millivolt gas heater, 20 1\/4\" wide, that hangs on an inside wall plate against an outside wall and vents straight through it with the standard vent kit in the carton; natural gas or propane, no chimney and no electricity.\u003c\/p\u003e\u003cp\u003eSealed combustion draws its air from outside, the standing pilot lights with the push-button piezo, and the gas valve runs on its own thermopile, so the furnace keeps heating when the power is out. The wall thermostat is not included: it takes an optional on\/off device - the \u003ca href=\"\/products\/empire-wall-thermostat-reed-switch-control-option\"\u003eTMV millivolt wall thermostat\u003c\/a\u003e, a wall switch, toggle switch or remote - and the optional \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-dvb1\"\u003eDVB1 automatic blower\u003c\/a\u003e for more even heat.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Wall Furnace (DV210\/DV215) family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e15,000 BTU\/hr direct vent:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a gravity direct vent wall furnace; combustion air in and flue gases out through one 6 1\/4\" wall opening; 65 to 66 percent AFUE per Empire's product guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeats without electricity:\u003c\/strong\u003e standing pilot with piezo ignition and a millivolt valve; add the thermostat, wall switch or remote of your choice (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent kit included:\u003c\/strong\u003e inside and outside wall plates, 5\" air inlet tube, 3\" flue outlet tube and vent cap for walls 4 1\/2\" to 13\" deep; the \u003ca href=\"\/products\/empire-vent-extension-kit-for-direct-vent-wall-furnace\"\u003eTH357 (natural gas) or TH358 (propane) vent extension kit\u003c\/a\u003e reach 19\" walls, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e (3\" deep) keeps the cap off vinyl siding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-dvb1\"\u003eDVB1 blower\u003c\/a\u003e (60 cu ft\/min), \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK1 vinyl siding kit, vent extension tubes and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDV215SGXNAT (natural gas), DV215SGXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e24 7\/8 x 20 1\/4 x 9 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 5 in air inlet tube, 3 in flue outlet tube; wall 4 1\/2 to 13 in (19 in with the extension tubes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e6 1\/4 in diameter minimum (plates cover up to 8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSides 1 in, top 12 in, floor 0 in; vent cap 20 in from an outside corner, 9 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 66 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e60 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent wall furnace\u003c\/li\u003e\n\u003cli\u003eComplete vent kit: inside wall plate, outside wall plate, 5\" air inlet tube, 3\" flue outlet tube, vent cap\u003c\/li\u003e\n\u003cli\u003eMounting hardware (#10 x 1 1\/2\" screws, Tinnerman nuts, toggle bolt, vent-cap screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: wall thermostat or other on\/off device, blower, vinyl siding kit, vent extension tubes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall between studs, hung on the inside wall plate over a 6 1\/4\" minimum opening; wall depth 4 1\/2\" to 13\" (to 19\" with the extension tubes); the vent is 2 inches right of center.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 1\" at the sides, 12\" above, 0\" to the floor (2\" suggested for future floor coverings); outside, the vent cap sits at least 20\" from an outside corner or obstruction, 9\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the optional on\/off device wires to the two valve wires and sits 4 to 5 ft up an interior wall in the same room; the blower plugs into a grounded three-prong receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpet or tile:\u003c\/strong\u003e on a combustible floor covering other than wood the furnace sits on a metal or wood panel its full width and depth; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213091016943,"sku":"DV215SGXNAT","price":1499.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213091049711,"sku":"DV215SGXLP","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DV210-215_06e3814e-0755-43d0-b02f-fc4ccbb186ab.jpg?v=1784547772"},{"product_id":"empire-37-dv25sg-direct-vent-millivolt-with-wall-thermostat-wall-furnace","title":"Empire 37\" DV25SG Direct-Vent Millivolt with Wall Thermostat Wall Furnace","description":"\u003cp\u003eThe Empire 37\" DV25SG Direct-Vent Millivolt with Wall Thermostat Wall Furnace is Empire's larger direct-vent wall furnace - a 25,000 BTU\/hr on natural gas (24,000 on propane) millivolt gas heater, 37\" wide, that hangs on a wall bracket against an outside wall and vents straight through it with the standard vent kit; the millivolt wall thermostat is in the box, and it needs no chimney and no electricity.\u003c\/p\u003e\u003cp\u003eSealed combustion draws its air from outside, the standing pilot lights with the push-button piezo, and the valve runs on its own thermopile, so the furnace keeps heating when the power is out. Add the optional \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-drb1\"\u003eDRB1 automatic blower\u003c\/a\u003e (75 cu ft\/min) for more air circulation; the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the vent cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Wall Furnace with Wall Thermostat (DV25\/DV35) family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25,000 BTU\/hr natural gas direct vent:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a gravity direct vent wall furnace; combustion air in and flue gases out through one 7 1\/2\" wall opening; 65 to 66 percent AFUE per Empire's product guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat included, no electricity:\u003c\/strong\u003e the millivolt wall thermostat mounts on an inside wall or on the furnace's own bracket; standing pilot with piezo ignition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent kit included:\u003c\/strong\u003e wall mounting bracket, outside mounting plate, 6\" air inlet tube, 4\" flue outlet tube and vent cap for walls 4 1\/2\" to 13\" deep; the DV983 \/ DV984 vent extension kits are listed for the DV35 only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-drb1\"\u003eDRB1 blower\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK-2 vinyl siding kit, the \u003ca href=\"\/products\/empire-4-gas-furnace-flue-outlet-vent-tube-extension\"\u003eDV844 flue outlet tube\u003c\/a\u003e and \u003ca href=\"\/products\/empire-6-gas-furnace-air-inlet-vent-tube-extension\"\u003eDV845 air inlet tube\u003c\/a\u003e listed in Empire's brochure for 13\" to 19\" walls, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDV25SGNAT (natural gas), DV25SGLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/hr natural gas; 24,000 BTU\/hr propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e28 x 37 x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eMillivolt wall thermostat included (interior wall or furnace bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube; wall 4 1\/2 to 13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e7 1\/2 in diameter; clear space 28 in high by 49 in wide; unit 4 in off the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eTop 48 in, each side 6 in, floor 4 in, rear 0 in; vent cap 24 in from an outside corner, 9 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 66 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e98 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent wall furnace\u003c\/li\u003e\n\u003cli\u003eMillivolt wall thermostat with mounting bracket\u003c\/li\u003e\n\u003cli\u003eComplete vent kit: wall mounting bracket, outside mounting plate, 6\" air inlet tube, 4\" flue outlet tube, vent cap\u003c\/li\u003e\n\u003cli\u003eMounting hardware (#10 x 1 1\/2\" screws, Tinnerman nuts, toggle bolts, vent-cap screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: blower, vinyl siding kit, vent extension kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall with a clear space 28\" high by 49\" wide, the 7 1\/2\" vent opening between studs (the vent is not centered on the furnace - use the carton template), the unit 4\" off the floor on its wall bracket; wall depth 4 1\/2\" to 13\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 48\" above, 6\" at each side, 4\" to the floor or floor covering, 0\" to the rear wall; outside, the vent cap sits at least 24\" from an outside corner or obstruction, 9\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit within the 13\" total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the thermostat wire follows the manual's gauge table (18 ga to 10 ft, 16 ga to 25 ft, 14 ga to 35 ft); the blower plugs into a grounded three-prong receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGarage:\u003c\/strong\u003e the burner sits at least 18\" above a residential garage floor, protected from vehicles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213094129903,"sku":"DV25SGNAT","price":1859.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213094162671,"sku":"DV25SGLP","price":1859.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DV25-35_05459cc4-1743-4934-9715-2fc95ae51ef2.jpg?v=1784547864"},{"product_id":"empire-37-dv35sg-direct-vent-millivolt-with-wall-thermostat-wall-furnace","title":"Empire 37\" DV35SG Direct-Vent Millivolt with Wall Thermostat Wall Furnace","description":"\u003cp\u003eThe Empire 37\" DV35SG Direct-Vent Millivolt with Wall Thermostat Wall Furnace is Empire's larger direct-vent wall furnace - a 35,000 BTU\/hr millivolt gas heater, 37\" wide, that hangs on a wall bracket against an outside wall and vents straight through it with the standard vent kit; the millivolt wall thermostat is in the box, and it needs no chimney and no electricity.\u003c\/p\u003e\u003cp\u003eSealed combustion draws its air from outside, the standing pilot lights with the push-button piezo, and the valve runs on its own thermopile, so the furnace keeps heating when the power is out. Add the optional \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-drb1\"\u003eDRB1 automatic blower\u003c\/a\u003e (75 cu ft\/min) for more air circulation; the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the vent cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Wall Furnace with Wall Thermostat (DV25\/DV35) family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e35,000 BTU\/hr direct vent:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a gravity direct vent wall furnace; combustion air in and flue gases out through one 7 1\/2\" wall opening; 65 to 66 percent AFUE per Empire's product guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat included, no electricity:\u003c\/strong\u003e the millivolt wall thermostat mounts on an inside wall or on the furnace's own bracket; standing pilot with piezo ignition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent kit included:\u003c\/strong\u003e wall mounting bracket, outside mounting plate, 6\" air inlet tube, 4\" flue outlet tube and vent cap for walls 4 1\/2\" to 13\" deep; the \u003ca href=\"\/products\/empire-vent-extension-kit-for-direct-vent-wall-furnace\"\u003eDV983 (natural gas) or DV984 (propane) vent extension kit\u003c\/a\u003e reaches 19\" walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-direct-vent-wall-furnace-accessory-drb1\"\u003eDRB1 blower\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK-2 vinyl siding kit, the \u003ca href=\"\/products\/empire-4-gas-furnace-flue-outlet-vent-tube-extension\"\u003eDV844 flue outlet tube\u003c\/a\u003e and \u003ca href=\"\/products\/empire-6-gas-furnace-air-inlet-vent-tube-extension\"\u003eDV845 air inlet tube\u003c\/a\u003e listed in Empire's brochure for 13\" to 19\" walls, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDV35SGNAT (natural gas), DV35SGLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e35,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e28 x 37 x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eMillivolt wall thermostat included (interior wall or furnace bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube; wall 4 1\/2 to 13 in (19 in with the DV983 \/ DV984 kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e7 1\/2 in diameter; clear space 28 in high by 49 in wide; unit 4 in off the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eTop 48 in, each side 6 in, floor 4 in, rear 0 in; vent cap 24 in from an outside corner, 9 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 66 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e101 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent wall furnace\u003c\/li\u003e\n\u003cli\u003eMillivolt wall thermostat with mounting bracket\u003c\/li\u003e\n\u003cli\u003eComplete vent kit: wall mounting bracket, outside mounting plate, 6\" air inlet tube, 4\" flue outlet tube, vent cap\u003c\/li\u003e\n\u003cli\u003eMounting hardware (#10 x 1 1\/2\" screws, Tinnerman nuts, toggle bolts, vent-cap screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: blower, vinyl siding kit, vent extension kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall with a clear space 28\" high by 49\" wide, the 7 1\/2\" vent opening between studs (the vent is not centered on the furnace - use the carton template), the unit 4\" off the floor on its wall bracket; wall depth 4 1\/2\" to 13\" (to 19\" with the DV983 \/ DV984 kit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 48\" above, 6\" at each side, 4\" to the floor or floor covering, 0\" to the rear wall; outside, the vent cap sits at least 24\" from an outside corner or obstruction, 9\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit within the 13\" total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the thermostat wire follows the manual's gauge table (18 ga to 10 ft, 16 ga to 25 ft, 14 ga to 35 ft); the blower plugs into a grounded three-prong receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGarage:\u003c\/strong\u003e the burner sits at least 18\" above a residential garage floor, protected from vehicles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213095604463,"sku":"DV35SGNAT","price":2009.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213095637231,"sku":"DV35SGLP","price":2009.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DV25-35_1dea865b-6017-4388-803b-b70524cfaa57.jpg?v=1784547912"},{"product_id":"empire-72-dvc35sppx-standing-pilot-direct-vent-counterflow-wall-furnace","title":"Empire 72\" DVC35SPPX Standing Pilot Direct-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 72\" DVC35SPPX Standing Pilot Direct-Vent Counterflow Wall Furnace is Empire's tall direct-vent counterflow furnace - a 35,000 BTU\/hr gas heater, 14 1\/8\" wide and 72 1\/2\" high, that stands against an outside wall, vents through it with sealed combustion, and pushes its heat out at floor level with a 275 cu ft\/min blower for even warmth across a large room; natural gas or propane, no chimney.\u003c\/p\u003e\u003cp\u003eIt has a standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights), runs the blower, fan control and limit switch on a household outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 10-inch side outlet kit\u003c\/a\u003e send warm air sideways or through the wall into an adjoining room, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e35,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type direct vent wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot:\u003c\/strong\u003e standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights); 120 V, less than 3 A, three-prong plug on a 3 ft cord.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits between studs:\u003c\/strong\u003e the 14 1\/8\" cabinet fits standard 16\" on-center framing and recesses up to 9 1\/2\" when no side outlets are used; wall depth 3\/4\" to 10\" (the DV1190 extended flue kit beyond that).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK2 vinyl siding kit, a vent tube extension kit for walls to 19\" through Empire's parts department, and Empire's gas conversion kits (by a qualified agency); the rear outlet kit and vent enclosures fit the FAW models only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDVC35SPPXNAT (natural gas), DVC35SPPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e35,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e275 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e72 1\/2 x 14 1\/8 x 10 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube, 7 1\/2 in wall opening; wall depth 3\/4 to 10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 9 1\/2 in between 16 in on-center studs (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in; vent cap 12 in from an outside corner, 9 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e115 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent counterflow wall furnace with its vent kit (air inlet tube, flue outlet tube, outside mounting plate, vent cap)\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: thermostat or other on\/off device, side outlet register or kit, vinyl siding kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall, the 7 1\/2\" vent opening between studs and the furnace fastened with toggle bolts at the top and screws at the floor, or recessed up to 9 1\/2\" between 16\" on-center studs (0\" to the sides and top in the recess; never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 4\" to a sidewall or combustible material (18\" with the flush SOR1 register), 4\" to the ceiling, 0\" to the floor and rear wall, 36\" in front recommended for service; outside, the vent cap sits at least 12\" from an outside corner, 9\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit within the 10\" total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and electrical:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; an optional on\/off device wires to the two valve wires 4 to 5 ft up an interior wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpet, tile and garages:\u003c\/strong\u003e on a combustible floor covering other than wood the furnace sits on a metal or wood panel its full width and depth; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213098979567,"sku":"DVC35SPPXNAT","price":2649.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213099012335,"sku":"DVC35SPPXLP","price":2649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DVC35SPPXNAT_509e5211-c012-4c55-b646-3f6a7d86521f.jpg?v=1784548015"},{"product_id":"empire-82-dvc55sppx-standing-pilot-direct-vent-counterflow-wall-furnace","title":"Empire 82\" DVC55SPPX Standing Pilot Direct-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 82\" DVC55SPPX Standing Pilot Direct-Vent Counterflow Wall Furnace is Empire's tall direct-vent counterflow furnace - a 55,000 BTU\/hr gas heater, 16\" wide and 82 3\/8\" high, that stands against an outside wall, vents through it with sealed combustion, and pushes its heat out at floor level with a 400 cu ft\/min blower for even warmth across a large room; natural gas or propane, no chimney.\u003c\/p\u003e\u003cp\u003eIt has a standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights), runs the blower, fan control and limit switch on a household outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 10-inch side outlet kit\u003c\/a\u003e send warm air sideways or through the wall into an adjoining room, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e55,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type direct vent wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot:\u003c\/strong\u003e standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights); matchless pushbutton piezo ignition per the brochure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside-wall mounting:\u003c\/strong\u003e the 16\" cabinet surface-mounts or recesses up to 4\" (a stud is repositioned to recess it); wall depth 4 1\/2\" to 13\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, a vent tube extension kit for walls to 19\" through Empire's parts department, and Empire's gas conversion kits (by a qualified agency); the rear outlet kit and vent enclosures fit the FAW models only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDVC55SPPXNAT (natural gas), DVC55SPPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e55,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e400 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e82 3\/8 x 16 x 11 5\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube, 7 1\/2 in wall opening; wall depth 4 1\/2 to 13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 4 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in; vent cap 24 in from an outside corner, 12 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e140 lb (two cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent counterflow wall furnace with its standard direct-vent cap for the outside wall\u003c\/li\u003e\n\u003cli\u003eNot included: thermostat or other on\/off device (control options are not included), side outlet register or kit, vinyl siding kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall (the brochure places the direct-vent counterflow models on outside walls), surface-mounted or recessed up to 4\"; 7 1\/2\" vent openings inside and out, wall depth 4 1\/2\" to 13\", vent projection 6\", vent cap 24\" from an outside corner or obstruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances (brochure):\u003c\/strong\u003e 4\" to the ceiling, 4\" at each side without a register or 18\" with the SOR1 register, zero to a wood floor; 7 3\/4\" wall-to-valve inlet reference in the brochure table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl options are not included:\u003c\/strong\u003e the furnace works with a manual control, toggle switch, thermostat, wall switch or remote control bought separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual edition:\u003c\/strong\u003e Empire publishes one DVC55 installation manual online and it names the IPX models; the brochure covers the DVC55SPPX. The counterflow brochure is in the Documents section below, and the installer follows the manual packed with the furnace. Installation and repair by a qualified service person to local codes or the National Fuel Gas Code.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213099864303,"sku":"DVC55SPPXNAT","price":2969.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213099897071,"sku":"DVC55SPPXLP","price":2969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DVC35SPPXNAT_fa341b7f-1f97-417e-9411-d67c993c1b67.jpg?v=1784548046"},{"product_id":"empire-82-dvc55ipx-intermittent-pilot-direct-vent-counterflow-wall-furnace","title":"Empire 82\" DVC55IPX Intermittent Pilot Direct-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 82\" DVC55IPX Intermittent Pilot Direct-Vent Counterflow Wall Furnace is Empire's tall direct-vent counterflow furnace - a 55,000 BTU\/hr gas heater, 16\" wide and 82 3\/8\" high, that stands against an outside wall, vents through it with sealed combustion, and pushes its heat out at floor level with a 400 cu ft\/min blower for even warmth across a large room; natural gas or propane, no chimney.\u003c\/p\u003e\u003cp\u003eIt has a intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds, runs the blower, fan control and limit switch on a household outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 10-inch side outlet kit\u003c\/a\u003e send warm air sideways or through the wall into an adjoining room, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e55,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type direct vent wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition:\u003c\/strong\u003e intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds; 120 V, less than 3 A, three-prong plug on a 3 ft cord.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside-wall mounting:\u003c\/strong\u003e the 16\" cabinet surface-mounts or recesses up to 4\" (a stud is repositioned to recess it); wall depth 4 1\/2\" to 13\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK2 vinyl siding kit, a vent tube extension kit for walls to 19\" through Empire's parts department, and Empire's gas conversion kits (by a qualified agency); the rear outlet kit and vent enclosures fit the FAW models only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDVC55IPXNAT (natural gas), DVC55IPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e55,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e400 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e82 3\/8 x 16 x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eIntermittent pilot (electronic), 90-second ignition trial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube, 7 1\/2 in wall opening; wall depth 4 1\/2 to 13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 4 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in; vent cap 24 in from an outside corner, 12 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e140 lb (two cartons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent counterflow wall furnace with its vent kit (air inlet tube, flue outlet tube, outside mounting plate, vent cap)\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: thermostat or other on\/off device, side outlet register or kit, vinyl siding kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall, the 7 1\/2\" vent opening between studs and the furnace fastened with toggle bolts at the top and screws at the floor, or recessed up to 4\" after a stud is repositioned (0\" to the sides and top in the recess; never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 4\" to a sidewall or combustible material (18\" with the flush SOR1 register), 4\" to the ceiling, 0\" to the floor and rear wall, 36\" in front recommended for service; outside, the vent cap sits at least 24\" from an outside corner, 12\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit within the 13\" total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and electrical:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; an optional on\/off device wires to the two valve wires 4 to 5 ft up an interior wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpet, tile and garages:\u003c\/strong\u003e on a combustible floor covering other than wood the furnace sits on a metal or wood panel its full width and depth; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213100060911,"sku":"DVC55IPXNAT","price":3559.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213100093679,"sku":"DVC55IPXLP","price":3559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DVC35SPPXNAT_5a7673bc-4979-4ea0-a68f-1e30fff88a59.jpg?v=1784548051"},{"product_id":"empire-72-dvc35ipx-intermittent-pilot-direct-vent-counterflow-wall-furnace","title":"Empire 72\" DVC35IPX Intermittent Pilot Direct-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 72\" DVC35IPX Intermittent Pilot Direct-Vent Counterflow Wall Furnace is Empire's tall direct-vent counterflow furnace - a 35,000 BTU\/hr gas heater, 14 1\/8\" wide and 72 1\/2\" high, that stands against an outside wall, vents through it with sealed combustion, and pushes its heat out at floor level with a 275 cu ft\/min blower for even warmth across a large room; natural gas or propane, no chimney.\u003c\/p\u003e\u003cp\u003eIt has a intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds, runs the blower, fan control and limit switch on a household outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 10-inch side outlet kit\u003c\/a\u003e send warm air sideways or through the wall into an adjoining room, and the \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e keeps the cap off vinyl siding.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Direct-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e35,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type direct vent wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition:\u003c\/strong\u003e intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds; 120 V, less than 3 A, three-prong plug on a 3 ft cord.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits between studs:\u003c\/strong\u003e the 14 1\/8\" cabinet fits standard 16\" on-center framing and recesses up to 9 1\/2\" when no side outlets are used; wall depth 3\/4\" to 10\" (the DV1190 extended flue kit beyond that).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vinyl-siding-vent-kit-direct-vent-wall-furnace-accessory\"\u003eDV822 vinyl siding vent kit\u003c\/a\u003e, VSK2 vinyl siding kit, a vent tube extension kit for walls to 19\" through Empire's parts department, and Empire's gas conversion kits (by a qualified agency); the rear outlet kit and vent enclosures fit the FAW models only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eDVC35IPXNAT (natural gas), DVC35IPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e35,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e275 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e72 1\/2 x 14 1\/8 x 10 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eIntermittent pilot (electronic), 90-second ignition trial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003eDirect vent through an outside wall: 6 in air inlet tube, 4 in flue outlet tube, 7 1\/2 in wall opening; wall depth 3\/4 to 10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 9 1\/2 in between 16 in on-center studs (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in; vent cap 12 in from an outside corner, 9 in from any building opening, 12 in above grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e115 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDirect-vent counterflow wall furnace with its vent kit (air inlet tube, flue outlet tube, outside mounting plate, vent cap)\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: thermostat or other on\/off device, side outlet register or kit, vinyl siding kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an outside wall, the 7 1\/2\" vent opening between studs and the furnace fastened with toggle bolts at the top and screws at the floor, or recessed up to 9 1\/2\" between 16\" on-center studs (0\" to the sides and top in the recess; never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 4\" to a sidewall or combustible material (18\" with the flush SOR1 register), 4\" to the ceiling, 0\" to the floor and rear wall, 36\" in front recommended for service; outside, the vent cap sits at least 12\" from an outside corner, 9\" from any opening into the building, 12\" above grade and 6 ft from any gas pressure regulator; on siding or near a projection the vent is spaced off the wall with 2 x 4 framing or the DV822 kit within the 10\" total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and electrical:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle (the IP model can be hard-wired when recessed); an optional on\/off device wires to the two valve wires 4 to 5 ft up an interior wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarpet, tile and garages:\u003c\/strong\u003e on a combustible floor covering other than wood the furnace sits on a metal or wood panel its full width and depth; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213100552431,"sku":"DVC35IPXNAT","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213100585199,"sku":"DVC35IPXLP","price":3159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/DVC35SPPXNAT_33a02350-eb07-462a-bc11-5f85c65b73b0.jpg?v=1784548069"},{"product_id":"empire-72-faw40sppx-standing-pilot-conventional-b-vent-counterflow-wall-furnace","title":"Empire 72\" FAW40SPPX Standing Pilot Conventional B-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 72\" FAW40SPPX Standing Pilot Conventional B-Vent Counterflow Wall Furnace is Empire's B-vent counterflow furnace - a 40,000 BTU\/hr gas heater, 14 1\/8\" wide and 72 1\/2\" high, that stands on an inside or outside wall, vents up through 4\" type B pipe, and pushes its heat out at floor level with a 275 cu ft\/min blower for even warmth across a large room; natural gas or propane.\u003c\/p\u003e\u003cp\u003eIt has a standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights), runs the blower, fan control, limit switch and manual-reset vent safety switch on an ordinary 120 V outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e send warm air into adjoining rooms, and the \u003ca href=\"\/products\/empire-vent-enclosure-for-faw40-conventional-b-vent-counterflow-wall-furnace\"\u003eFVE24DB \/ FVE34DB \/ FVE46DB vent enclosures\u003c\/a\u003e dress the vent pipe above a surface-mounted furnace.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Conventional B-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type vented wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level; a washable permanent filter in the door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot:\u003c\/strong\u003e standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights); 120 V, less than 3 A, three-prong plug on a 3 ft cord; the vent safety switch shuts the burners off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits between studs:\u003c\/strong\u003e the 14 1\/8\" cabinet fits typical stud spacing and recesses up to 9 1\/2\" when no side outlets are used (3\/4\" minimum above the heater, no combustible header on top).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vent-enclosure-for-faw40-conventional-b-vent-counterflow-wall-furnace\"\u003eFVE24DB \/ FVE34DB \/ FVE46DB vent enclosures\u003c\/a\u003e by room height, the DV648 oval-to-round flue adapter kit, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eFAW40SPPXNAT (natural gas), FAW40SPPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e275 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e72 1\/2 x 14 1\/8 x 10 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B-1 (or B-W) vent collar; 4 in round with the DV648 adapter; vent parts purchased locally; vent cap at least 12 ft above the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 9 1\/2 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e110 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eB-vent counterflow wall furnace with draft diverter, vent safety switch and header baseplate gasket\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, outlet kits, vent enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an inside or outside wall, fastened with toggle bolts at the top and screws at the floor, or recessed up to 9 1\/2\" (between typical studs; 0\" to the sides in the recess, never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e 4\" oval type B-1 or B-W pipe from the draft diverter straight up through the wall cavity on a listed baseplate with ceiling plate spacers (fire-stop spacers on each further floor), or 4\" round with the DV648 adapter; no elbow directly on the diverter; the chimney ends at least 3 ft above the roof penetration and 2 ft above anything within 10 ft; never shared with a solid-fuel appliance; an insulated vent enclosure is recommended under flat roofs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" to a sidewall (18\" with the flush SOR1 register), 4\" to the ceiling, 0\" to the floor and rear wall; the furnace needs combustion and ventilation air - a confined space gets two permanent openings (within 12\" of the ceiling and of the floor) sized per the National Fuel Gas Code, never from a space with exhaust fans or a fireplace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas, electrical and outlets:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg (1\/2\" pipe up to 75 ft of natural gas run, 3\/4\" beyond); the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; the rear outlet's wall opening (12 1\/8\" wide by 8 1\/2\" high, 10 11\/16\" above the floor) is cut before the furnace is attached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer service:\u003c\/strong\u003e Empire sells, services and warrants through its dealers - warranty claims go to the selling dealer, a non-qualified installation voids the warranty, and annual documented service keeps it in force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213100650735,"sku":"FAW40SPPXNAT","price":2319.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213100683503,"sku":"FAW40SPPXLP","price":2319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/FAW40SPPXNAT_b5100c00-2cac-431b-948f-39b6b421f5b9.jpg?v=1784548075"},{"product_id":"empire-72-faw40ipx-intermittent-pilot-conventional-b-vent-counterflow-wall-furnace","title":"Empire 72\" FAW40IPX Intermittent Pilot Conventional B-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 72\" FAW40IPX Intermittent Pilot Conventional B-Vent Counterflow Wall Furnace is Empire's B-vent counterflow furnace - a 40,000 BTU\/hr gas heater, 14 1\/8\" wide and 72 1\/2\" high, that stands on an inside or outside wall, vents up through 4\" type B pipe, and pushes its heat out at floor level with a 275 cu ft\/min blower for even warmth across a large room; natural gas or propane.\u003c\/p\u003e\u003cp\u003eIt has a intermittent pilot with a Honeywell SmartValve that lights the pilot itself on every call for heat, runs the blower, fan control, limit switch and manual-reset vent safety switch on an ordinary 120 V outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e send warm air into adjoining rooms, and the \u003ca href=\"\/products\/empire-vent-enclosure-for-faw40-conventional-b-vent-counterflow-wall-furnace\"\u003eFVE24DB \/ FVE34DB \/ FVE46DB vent enclosures\u003c\/a\u003e dress the vent pipe above a surface-mounted furnace.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Conventional B-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type vented wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level; a washable permanent filter in the door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition:\u003c\/strong\u003e intermittent pilot with a Honeywell SmartValve that lights the pilot itself on every call for heat; 120 V, less than 3 A, three-prong plug on a 3 ft cord; the vent safety switch shuts the burners off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits between studs:\u003c\/strong\u003e the 14 1\/8\" cabinet fits typical stud spacing and recesses up to 9 1\/2\" when no side outlets are used (3\/4\" minimum above the heater, no combustible header on top).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vent-enclosure-for-faw40-conventional-b-vent-counterflow-wall-furnace\"\u003eFVE24DB \/ FVE34DB \/ FVE46DB vent enclosures\u003c\/a\u003e by room height, the DV648 oval-to-round flue adapter kit, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eFAW40IPXNAT (natural gas), FAW40IPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e275 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e72 1\/2 x 14 1\/8 x 10 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eIntermittent pilot (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B-1 (or B-W) vent collar; 4 in round with the DV648 adapter; vent parts purchased locally; vent cap at least 12 ft above the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 9 1\/2 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 4 in, floor and rear 0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e110 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eB-vent counterflow wall furnace with draft diverter, vent safety switch and header baseplate gasket\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, outlet kits, vent enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an inside or outside wall, fastened with toggle bolts at the top and screws at the floor, or recessed up to 9 1\/2\" (between typical studs; 0\" to the sides in the recess, never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e 4\" oval type B-1 or B-W pipe from the draft diverter straight up through the wall cavity on a listed baseplate with ceiling plate spacers (fire-stop spacers on each further floor), or 4\" round with the DV648 adapter; no elbow directly on the diverter; the chimney ends at least 3 ft above the roof penetration and 2 ft above anything within 10 ft; never shared with a solid-fuel appliance; an insulated vent enclosure is recommended under flat roofs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" to a sidewall (18\" with the flush SOR1 register), 4\" to the ceiling, 0\" to the floor and rear wall; the furnace needs combustion and ventilation air - a confined space gets two permanent openings (within 12\" of the ceiling and of the floor) sized per the National Fuel Gas Code, never from a space with exhaust fans or a fireplace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas, electrical and outlets:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg (1\/2\" pipe up to 75 ft of natural gas run, 3\/4\" beyond); the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; the rear outlet's wall opening (12 1\/8\" wide by 8 1\/2\" high, 10 11\/16\" above the floor) is cut before the furnace is attached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer service:\u003c\/strong\u003e Empire sells, services and warrants through its dealers - warranty claims go to the selling dealer, a non-qualified installation voids the warranty, and annual documented service keeps it in force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213101469935,"sku":"FAW40IPXNAT","price":2849.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213101502703,"sku":"FAW40IPXLP","price":2849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/FAW40SPPXNAT_348941e8-1f0e-406d-b22b-bca0173c8ce9.jpg?v=1784548098"},{"product_id":"empire-82-faw55sppx-standing-pilot-conventional-b-vent-counterflow-wall-furnace","title":"Empire 82\" FAW55SPPX Standing Pilot Conventional B-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 82\" FAW55SPPX Standing Pilot Conventional B-Vent Counterflow Wall Furnace is Empire's B-vent counterflow furnace - a 55,000 BTU\/hr gas heater, 16\" wide and 82 3\/8\" high, that stands on an inside or outside wall, vents up through 4\" type B pipe, and pushes its heat out at floor level with a 400 cu ft\/min blower for even warmth across a large room; natural gas or propane.\u003c\/p\u003e\u003cp\u003eIt has a standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights), runs the blower, fan control, limit switch and manual-reset vent safety switch on an ordinary 120 V outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e send warm air into adjoining rooms, and the \u003ca href=\"\/products\/empire-vent-enclosure-for-faw55-conventional-b-vent-counterflow-wall-furnace\"\u003eDV651DB \/ DV665DB \/ DV666DB vent enclosures\u003c\/a\u003e dress the vent pipe above a surface-mounted furnace.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Conventional B-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e55,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type vented wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level; a washable permanent filter in the door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot:\u003c\/strong\u003e standing pilot lit with the piezo ignitor (the red reset button held while the pilot lights); 120 V, less than 3 A, three-prong plug on a 3 ft cord; the vent safety switch shuts the burners off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface mount or shallow recess:\u003c\/strong\u003e the 16\" cabinet surface-mounts, or recesses up to 4\" after a stud is repositioned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vent-enclosure-for-faw55-conventional-b-vent-counterflow-wall-furnace\"\u003eDV651DB \/ DV665DB \/ DV666DB vent enclosures\u003c\/a\u003e by room height, the DV648 oval-to-round flue adapter kit, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eFAW55SPPXNAT (natural gas), FAW55SPPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e55,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e400 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e82 3\/8 x 16 x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot, piezo ignitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B-1 (or B-W) vent collar; 4 in round with the DV648 adapter; vent parts purchased locally; vent cap at least 12 ft above the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 4 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 7 1\/2 in, floor and rear 0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e135 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eB-vent counterflow wall furnace with draft diverter, vent safety switch and header baseplate gasket\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, outlet kits, vent enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an inside or outside wall, fastened with toggle bolts at the top and screws at the floor, or recessed up to 4\" (after a stud is repositioned; 0\" to the sides in the recess, never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e 4\" oval type B-1 or B-W pipe from the draft diverter straight up through the wall cavity on a listed baseplate with ceiling plate spacers (fire-stop spacers on each further floor), or 4\" round with the DV648 adapter; no elbow directly on the diverter; the chimney ends at least 3 ft above the roof penetration and 2 ft above anything within 10 ft; never shared with a solid-fuel appliance; an insulated vent enclosure is recommended under flat roofs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" to a sidewall (18\" with the flush SOR1 register), 7 1\/2\" to the ceiling, 0\" to the floor and rear wall; the furnace needs combustion and ventilation air - a confined space gets two permanent openings (within 12\" of the ceiling and of the floor) sized per the National Fuel Gas Code, never from a space with exhaust fans or a fireplace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas, electrical and outlets:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg (1\/2\" pipe up to 15 ft of natural gas run, 3\/4\" beyond); the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; the rear outlet's wall opening (12 1\/8\" wide by 8 1\/2\" high, 14 3\/4\" above the floor) is cut before the furnace is attached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer service:\u003c\/strong\u003e Empire sells, services and warrants through its dealers - warranty claims go to the selling dealer, a non-qualified installation voids the warranty, and annual documented service keeps it in force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213101568239,"sku":"FAW55SPPXNAT","price":2649.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213101601007,"sku":"FAW55SPPXLP","price":2649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/FAW55SPPXNAT-1_d1152bed-0f6c-4ca2-9f71-da438960d8f3.jpg?v=1784548104"},{"product_id":"empire-82-faw55ipx-intermittent-pilot-conventional-b-vent-counterflow-wall-furnace","title":"Empire 82\" FAW55IPX Intermittent Pilot Conventional B-Vent Counterflow Wall Furnace","description":"\u003cp\u003eThe Empire 82\" FAW55IPX Intermittent Pilot Conventional B-Vent Counterflow Wall Furnace is Empire's B-vent counterflow furnace - a 55,000 BTU\/hr gas heater, 16\" wide and 82 3\/8\" high, that stands on an inside or outside wall, vents up through 4\" type B pipe, and pushes its heat out at floor level with a 400 cu ft\/min blower for even warmth across a large room; natural gas or propane.\u003c\/p\u003e\u003cp\u003eIt has a intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds, runs the blower, fan control, limit switch and manual-reset vent safety switch on an ordinary 120 V outlet, and takes an optional on\/off device (wall switch, remote, toggle switch or thermostat) at the valve. The \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e and \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e send warm air into adjoining rooms, and the \u003ca href=\"\/products\/empire-vent-enclosure-for-faw55-conventional-b-vent-counterflow-wall-furnace\"\u003eDV651DB \/ DV665DB \/ DV666DB vent enclosures\u003c\/a\u003e dress the vent pipe above a surface-mounted furnace.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire Conventional B-Vent Counterflow Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e55,000 BTU\/hr counterflow:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a fan type vented wall furnace; up to 76 percent AFUE per Empire's brochure and product guide; warm air exits at floor level; a washable permanent filter in the door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic ignition:\u003c\/strong\u003e intermittent pilot that lights itself on every call for heat and locks out if the pilot fails to light within 90 seconds; 120 V, less than 3 A, three-prong plug on a 3 ft cord; the vent safety switch shuts the burners off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface mount or shallow recess:\u003c\/strong\u003e the 16\" cabinet surface-mounts, or recesses up to 4\" after a stud is repositioned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-side-outlet-register-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOR1 side outlet register\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-side-outlet-kit-direct-vent-counterflow-wall-furnace-accessory\"\u003eSOK1 side outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-10-rear-outlet-kit-direct-vent-counterflow-furnace-accessory\"\u003eROK1 rear outlet kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-vent-enclosure-for-faw55-conventional-b-vent-counterflow-wall-furnace\"\u003eDV651DB \/ DV665DB \/ DV666DB vent enclosures\u003c\/a\u003e by room height, the DV648 oval-to-round flue adapter kit, and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eFAW55IPXNAT (natural gas), FAW55IPXLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e55,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower output\u003c\/td\u003e\n\u003ctd\u003e400 cu ft\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e82 3\/8 x 16 x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eIntermittent pilot (electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e120 V, 60 Hz, less than 3 A; three-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B-1 (or B-W) vent collar; 4 in round with the DV648 adapter; vent parts purchased locally; vent cap at least 12 ft above the floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecess\u003c\/td\u003e\n\u003ctd\u003eUp to 4 in (not with side outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSidewall 4 in (18 in with the SOR1 register), ceiling 7 1\/2 in, floor and rear 0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e75 to 76 percent AFUE (Empire brochure \/ product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eBeige\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e135 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eB-vent counterflow wall furnace with draft diverter, vent safety switch and header baseplate gasket\u003c\/li\u003e\n\u003cli\u003e3 ft three-prong plug assembly and strain-relief bushing\u003c\/li\u003e\n\u003cli\u003eMounting hardware (toggle bolts, #10 screws) and wall template\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, outlet kits, vent enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e on an inside or outside wall, fastened with toggle bolts at the top and screws at the floor, or recessed up to 4\" (after a stud is repositioned; 0\" to the sides in the recess, never recessed with side outlets); the baseboard behind the furnace comes off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e 4\" oval type B-1 or B-W pipe from the draft diverter straight up through the wall cavity on a listed baseplate with ceiling plate spacers (fire-stop spacers on each further floor), or 4\" round with the DV648 adapter; no elbow directly on the diverter; the chimney ends at least 3 ft above the roof penetration and 2 ft above anything within 10 ft; never shared with a solid-fuel appliance; an insulated vent enclosure is recommended under flat roofs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" to a sidewall (18\" with the flush SOR1 register), 7 1\/2\" to the ceiling, 0\" to the floor and rear wall; the furnace needs combustion and ventilation air - a confined space gets two permanent openings (within 12\" of the ceiling and of the floor) sized per the National Fuel Gas Code, never from a space with exhaust fans or a fireplace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas, electrical and outlets:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg (1\/2\" pipe up to 15 ft of natural gas run, 3\/4\" beyond); the plug cord leaves through a 7\/8\" knockout in either side panel to a grounded 120 V receptacle; the rear outlet's wall opening (12 1\/8\" wide by 8 1\/2\" high, 14 3\/4\" above the floor) is cut before the furnace is attached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer service:\u003c\/strong\u003e Empire sells, services and warrants through its dealers - warranty claims go to the selling dealer, a non-qualified installation voids the warranty, and annual documented service keeps it in force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas","offer_id":50213105402095,"sku":"FAW55IPXNAT","price":3239.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50213105434863,"sku":"FAW55IPXLP","price":3239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/FAW55SPPXNAT-1_2b632fde-1129-4445-b575-8394e37819c8.jpg?v=1784548172"},{"product_id":"empire-66-gwth25-35w-b-vent-gravity-wall-furnace","title":"Empire 66\" GWTH25\/35W B-Vent Gravity Wall Furnace","description":"\u003cp\u003eThe Empire GWT25W \/ GWT35W B-Vent Gravity Wall Furnace is Empire's in-wall gravity furnace - a 25,000 or 35,000 BTU\/hr millivolt gas heater, 16\" wide and 6\" deep, that recesses into a standard 2 x 4 stud wall and vents up through 4\" oval type B pipe; no electricity, no chimney, natural gas or propane, and the common size retrofits into the opening of an older wall furnace.\u003c\/p\u003e\u003cp\u003eIn-shot burners light instantly off a standing pilot, the valve runs on its own thermopile, and the furnace ships without a thermostat: it takes an optional on\/off device - a millivolt wall thermostat, wall switch, toggle switch or remote. The \u003ca href=\"\/products\/empire-automatic-blower-for-b-vent-gravity-wall-furnace\"\u003eGWTB2W automatic blower\u003c\/a\u003e mounts above the casing for more circulation, the \u003ca href=\"\/products\/empire-rear-register-kit-for-b-vent-gravity-wall-furnace\"\u003eGWTR1W rear register kit\u003c\/a\u003e sends part of the heat into the room behind, and the \u003ca href=\"\/products\/empire-out-of-wall-installation-kit-for-b-vent-gravity-wall-furnace\"\u003eGWTW2W out-of-wall kit\u003c\/a\u003e surface-mounts the furnace on a solid wall.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire B-Vent Gravity Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25,000 or 35,000 BTU\/hr gravity vent:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a vented wall furnace; 65 to 70 percent AFUE per Empire's product guide; in-shot burners and a tubular heat exchanger; works without electricity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits a 2 x 4 wall:\u003c\/strong\u003e rough-in opening 14 1\/2\" wide by 66 1\/8\" high between studs 16\" on center; the header plate with the vent baseplate gasket comes with the furnace, the 4\" oval B-vent is bought locally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot, thermostat not included:\u003c\/strong\u003e millivolt valve with a manual-reset vent safety switch on the draft diverter; add the control of your choice (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-for-b-vent-gravity-wall-furnace\"\u003eGWTB2W blower\u003c\/a\u003e (75 cu ft\/min; the furnace stands 71 7\/8\" with it), \u003ca href=\"\/products\/empire-rear-register-kit-for-b-vent-gravity-wall-furnace\"\u003eGWTR1W rear register kit\u003c\/a\u003e, \u003ca href=\"\/products\/empire-out-of-wall-installation-kit-for-b-vent-gravity-wall-furnace\"\u003eGWTW2W out-of-wall kit\u003c\/a\u003e (not combined with the rear register), and Empire's gas conversion kits (by a qualified agency).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eGWT25WNAT \/ GWT35WNAT (natural gas), GWT25WLP \/ GWT35WLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e25,000 BTU\/hr (GWT25W) or 35,000 BTU\/hr (GWT35W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e66 1\/8 x 16 x 6 in (71 7\/8 in high with the blower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B pipe (B-1 or B-W); no vent equipment supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e14 1\/2 x 66 1\/8 in in a 2 x 4 stud wall, 16 in on center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSides 4 in, top 12 in, floor (or carpet \/ tile) 1 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 70 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGravity wall furnace with header plate assembly and baseplate gasket, outer casing and control door\u003c\/li\u003e\n\u003cli\u003eHardware package and match holder\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, blower, rear register kit, out-of-wall kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e near the center of the space to be heated so overflow heat reaches adjoining rooms; never in a closet, alcove or small hallway that doors can isolate, nor where a door swings over the casing; a 14 1\/2\" by 66 1\/8\" rough-in opening from the top of the floor plate in 2 x 4 framing with 1\/4\" to 5\/8\" sheeting (a solid wall takes the GWTW2W out-of-wall kit instead).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e the baseplate (bought locally) screws to the header plate, the 4\" oval double-wall B-vent snaps into it and runs up inside the stud space at least 6 ft above the header with ceiling plate spacers and fire-stop spacers on each further floor; an insulated vent enclosure is recommended under flat roofs; the manual-reset vent safety switch shuts the main burner off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore the furnace goes in:\u003c\/strong\u003e the rear register's wall hole is cut and the blower's hard wiring (if used) completed before the header plate is installed; the wall is plastered with plain gypsum lath around the recess.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" at the sides, 12\" above, 1 1\/2\" to the floor and to the top of carpet or tile; in a tight building the room gets two permanent combustion-air openings (near the top and near the bottom) of at least 1 sq in per 2,000 BTU\/hr of input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the optional millivolt on\/off device wires to the two valve wires and sits 4 to 5 ft up an interior wall in the same room, never behind the header flanges; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Natural Gas \/ 25000","offer_id":50213105598703,"sku":"GWT25WNAT","price":1299.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ 35000","offer_id":50213105631471,"sku":"GWT35WNAT","price":1399.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ 25000","offer_id":50213105664239,"sku":"GWT25WLP","price":1299.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ 35000","offer_id":50213105697007,"sku":"GWT35WLP","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/GWT25WNAT_ddb18cee-a2fc-4cd6-8eae-fa13d3d81435.jpg?v=1784548180"},{"product_id":"empire-66-gwt50w-b-vent-gravity-wall-furnace","title":"Empire 66\" GWT50W B-Vent Gravity Wall Furnace","description":"\u003cp\u003eThe Empire 66\" GWT50W B-Vent Gravity Wall Furnace is Empire's dual-wall gravity furnace - a 50,000 BTU\/hr millivolt gas heater that recesses into a standard 2 x 4 wall between two adjoining rooms and warms both, 25,000 BTU\/hr to each side; 16\" wide and 6\" deep, no electricity, no chimney, natural gas or propane.\u003c\/p\u003e\u003cp\u003eIn-shot burners light instantly off a standing pilot, the valve runs on its own thermopile, and the furnace ships without a thermostat: it takes an optional on\/off device - a millivolt wall thermostat, wall switch, toggle switch or remote. The \u003ca href=\"\/products\/empire-automatic-blower-for-b-vent-gravity-wall-furnace\"\u003eGWTB2W automatic blower\u003c\/a\u003e mounts above the casing for more circulation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThis listing is part of the Empire B-Vent Gravity Wall Furnace family - use the selector above to compare the models.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50,000 BTU\/hr dual wall:\u003c\/strong\u003e design certified to ANSI Z21.86 \/ CSA 2.32 as a vented wall furnace; warm air discharges into the two rooms that share the wall, 25,000 BTU\/hr each; 65 to 70 percent AFUE per Empire's product guide; works without electricity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits a 2 x 4 wall:\u003c\/strong\u003e rough-in opening 14 1\/2\" wide by 66 1\/8\" high between studs 16\" on center; the header plate with the vent baseplate gasket comes with the furnace, the 4\" oval B-vent is bought locally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding pilot, thermostat not included:\u003c\/strong\u003e millivolt valve with a manual-reset vent safety switch on the draft diverter; add the control of your choice (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed accessories:\u003c\/strong\u003e \u003ca href=\"\/products\/empire-automatic-blower-for-b-vent-gravity-wall-furnace\"\u003eGWTB2W blower\u003c\/a\u003e (75 cu ft\/min; one may be fitted on each side), and Empire's gas conversion kits (by a qualified agency); the rear register and out-of-wall kits fit the single-wall models only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpire space-heating warranty:\u003c\/strong\u003e limited 10-year parts on the combustion chamber, 1-year parts on remote controls, thermostats, accessories and parts - original purchaser, qualified installer, serviced annually.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eGWT50WNAT (natural gas), GWT50WLP (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e50,000 BTU\/hr total, 25,000 BTU\/hr to each room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e66 1\/8 x 16 x 6 in (71 7\/8 in high with the blower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas inlet\u003c\/td\u003e\n\u003ctd\u003e1\/2 in pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent\u003c\/td\u003e\n\u003ctd\u003e4 in oval type B pipe (B-1 or B-W); no vent equipment supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eStanding pilot; millivolt valve - no electricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eOptional on\/off device (wall thermostat, wall switch, toggle switch or remote); thermostat not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall opening\u003c\/td\u003e\n\u003ctd\u003e14 1\/2 x 66 1\/8 in in a 2 x 4 stud wall, 16 in on center; GWT50W: 2 x 4 construction only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eSides 4 in, top 12 in, floor (or carpet \/ tile) 1 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e65 to 70 percent AFUE (Empire product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e133 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited 10-year parts on the combustion chamber; 1-year parts on controls, accessories and parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGravity wall furnace with header plate assembly and baseplate gasket, outer casing and control door\u003c\/li\u003e\n\u003cli\u003eHardware package and match holder\u003c\/li\u003e\n\u003cli\u003eInstallation instructions and owner's manual\u003c\/li\u003e\n\u003cli\u003eNot included: type B vent pipe, baseplate and spacers (purchased locally), thermostat or other on\/off device, blower\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhere it goes:\u003c\/strong\u003e near the center of the space to be heated so overflow heat reaches adjoining rooms - the GWT50W sits in the wall between the two rooms it heats; never in a closet, alcove or small hallway that doors can isolate, nor where a door swings over the casing; a 14 1\/2\" by 66 1\/8\" rough-in opening from the top of the floor plate in 2 x 4 framing with 1\/4\" to 5\/8\" sheeting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e the baseplate (bought locally) screws to the header plate, the 4\" oval double-wall B-vent snaps into it and runs up inside the stud space at least 6 ft above the header with ceiling plate spacers and fire-stop spacers on each further floor; an insulated vent enclosure is recommended under flat roofs; the manual-reset vent safety switch shuts the main burner off on spillage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore the furnace goes in:\u003c\/strong\u003e the blower's hard wiring (if used) is completed before the header plate is installed; the wall is plastered with plain gypsum lath around the recess.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances and air:\u003c\/strong\u003e 4\" at the sides, 12\" above, 1 1\/2\" to the floor and to the top of carpet or tile; in a tight building the room gets two permanent combustion-air openings (near the top and near the bottom) of at least 1 sq in per 2,000 BTU\/hr of input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas and controls:\u003c\/strong\u003e 1\/2\" gas inlet with its own shut-off, union and drip leg; the optional millivolt on\/off device wires to the two valve wires and sits 4 to 5 ft up an interior wall in the same room, never behind the header flanges; in a garage the burner sits at least 18\" above the floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer:\u003c\/strong\u003e gas piping, installation and service by a qualified agency (in Massachusetts a licensed plumber or gas fitter) to local codes or the National Fuel Gas Code; natural gas and propane models are built for one gas and converted only with Empire's certified kit - order the variant for your gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced 4 percent per 1,000 ft (the manual prints the Canadian manifold pressures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e the installation instructions and owner's manual (specifications, clearances, wall opening, venting, lighting, parts list, warranty) and the Empire Heating Systems brochure are in the Documents section below.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Empire Comfort Systems","offers":[{"title":"Propane","offer_id":50213107237103,"sku":"GWT50WLP","price":1889.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas","offer_id":50213107269871,"sku":"GWT50WNAT","price":1889.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/empire_GWT50WLP-2_38b35267-6bae-408d-a6c0-1248767e7f32.jpg?v=1784548211"}],"url":"https:\/\/hearthdepot.com\/collections\/empire-wall-furnaces.oembed","provider":"Hearth Depot","version":"1.0","type":"link"}