{"title":"Superior Triple-Flame Gas Logs","description":null,"products":[{"product_id":"superior-rugged-stack-triple-flame-18-concrete-vent-free-gas-log-set","title":"Superior Rugged Stack Triple-Flame 18\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF18RS is a gas log set in 18\" (Innovative Hearth Products). Fits TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner; installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF18RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e6 logs (bottom ember log, rear, right front, left front, right crossover, left crossover) plus switch log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e28,000–24,000 BTU\/hr (TF18NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eRugged Stack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e28\" W × 20\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e24\" × 14\" × 13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Rugged Stack log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003cli\u003eTwo ember materials (Platinum Bright Embers and Glowing Embers)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner; installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545785700591,"sku":"LTF18RS","price":309.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Rugged_Stack_349f2792-9c50-40e8-ab18-52945e8f63b9.jpg?v=1787051737"},{"product_id":"superior-rugged-stack-triple-flame-24-concrete-vent-free-gas-log-set","title":"Superior Rugged Stack Triple-Flame 24\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF24RS is a gas log set in 24\" (Innovative Hearth Products). Fits TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs).\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF24RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e6 logs (bottom ember log, rear, right front, left front, right crossover, left crossover) plus switch log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e39,000–28,000 BTU\/hr (TF2430NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eRugged Stack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e32\" W × 22\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e72 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e24\" × 14\" × 13.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Rugged Stack log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003cli\u003eTwo ember materials (Platinum Bright Embers and Glowing Embers)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545787207919,"sku":"LTF24RS","price":349.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Rugged_Stack_2da4303d-5eae-418d-a6bc-314adfc800d0.jpg?v=1787051741"},{"product_id":"superior-rugged-stack-triple-flame-30-concrete-vent-free-gas-log-set","title":"Superior Rugged Stack Triple-Flame 30\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF30RS is a gas log set in 30\" (Innovative Hearth Products). Fits TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs).\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF30RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e6 logs (bottom ember log, rear, right front, left front, right crossover, left crossover) plus switch log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e39,000–28,000 BTU\/hr (TF2430NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eRugged Stack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e40\" W × 30\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e75 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e24\" × 14\" × 13.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Rugged Stack log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003cli\u003eTwo ember materials (Platinum Bright Embers and Glowing Embers)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545791959279,"sku":"LTF30RS","price":389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Rugged_Stack_cf58d5e5-0fdb-49f5-8a8d-6bfc454877e6.jpg?v=1787051745"},{"product_id":"superior-wild-timber-triple-flame-18-concrete-vent-free-gas-log-set","title":"Superior Wild Timber Triple-Flame 18\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF18WT is a gas log set in 18\" (Innovative Hearth Products). Fits TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner; installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF18WT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF2078\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e8 logs (back bottom, middle bottom, front left bottom, front right bottom, back left top, far right top, left 'Y' top, front top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e28,000–24,000 BTU\/hr (TF18NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eWild Timber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e28\" W × 20\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e51 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 18.5\" × 9.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Wild Timber log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF18NE\/TF18PE (electronic), TF18NR\/TF18PR (millivolt remote-ready), TF18NV\/TF18PV (variable) — 18\" Triple-Flame burner; installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545793597679,"sku":"LTF18WT","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Triple-Flame_Burner-1_68a37900-4b0c-4e89-8360-216afe439186.jpg?v=1787051750"},{"product_id":"superior-wild-timber-triple-flame-24-concrete-vent-free-gas-log-set","title":"Superior Wild Timber Triple-Flame 24\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF24WT is a gas log set in 24\" (Innovative Hearth Products). Fits TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs).\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF24WT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF2079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e8 logs (back bottom, middle bottom, front left bottom, front right bottom, back left top, far right top, left 'Y' top, front top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e39,000–28,000 BTU\/hr (TF2430NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eWild Timber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e32\" W × 22\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e51 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 18.5\" × 9.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Wild Timber log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545794646255,"sku":"LTF24WT","price":279.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Triple-Flame_Burner-1_2596c4d5-8cb4-4f12-9d02-d86de6ab21f0.jpg?v=1787051755"},{"product_id":"superior-wild-timber-triple-flame-30-concrete-vent-free-gas-log-set","title":"Superior Wild Timber Triple-Flame 30\" Concrete Vent-Free Gas Log Set","description":"\u003cp\u003eThe Superior LTF30WT is a gas log set in 30\" (Innovative Hearth Products). Fits TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs).\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Listed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLTF30WT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF2080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Material\u003c\/td\u003e\n\u003ctd\u003eConcrete (cast refractory concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiece Count\u003c\/td\u003e\n\u003ctd\u003e8 logs (back bottom, middle bottom, front left bottom, front right bottom, back left top, far right top, left 'Y' top, front top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (unvented) log set; for use in a masonry or UL127 factory-built fireplace or a listed vent-free firebox with the Triple-Flame burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or Propane — determined by the burner model (N = NG, P = LP); logs are fuel-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Burner Platform\u003c\/td\u003e\n\u003ctd\u003eTF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum \/ Approved Input\u003c\/td\u003e\n\u003ctd\u003e39,000–28,000 BTU\/hr (TF2430NE\/PE, NG or LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Style\u003c\/td\u003e\n\u003ctd\u003eWild Timber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eListed as part of the Triple-Flame vent-free gas log heater system — PFS, ANSI Z21.11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Size\u003c\/td\u003e\n\u003ctd\u003e40\" W × 30\" rear W × 19\" H × 14\" D minimum firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e65 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e30\" × 18.5\" × 9.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComplete Wild Timber log set\u003c\/li\u003e\n\u003cli\u003eLog placement instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame burner required, sold separately — TF2430NE\/TF2430PE (electronic), TF2430NR\/TF2430PR (millivolt), TF2430NV\/TF2430PV (variable) — 24\" Triple-Flame burner (serves 24\" and 30\" logs); installation of these logs on any other burner is strictly prohibited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Decorative volcanic stone (FDVS), floor media kit (FM100), damper clamp GA6080, hood GA6050, remote\/wall controls\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50545795334383,"sku":"LTF30WT","price":319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Triple-Flame_Burner-1_83bf740a-a09b-4e56-ae8f-c8c73ce7a48e.jpg?v=1787051760"},{"product_id":"superior-triple-flame-18-vent-free-burner-with-ember-bed","title":"Superior Triple-Flame 18\" Vent-Free Burner with Ember Bed","description":"\u003cp\u003eThe Superior TF18 is a gas burner in 18\" (Innovative Hearth Products). Fits LTF18RS, LTF18WT (Rugged Stack \/ Wild Timber).\u003c\/p\u003e\u003cp\u003eThis listing covers 6 variants — use the selectors above to choose the correct model.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame vent-free log set (required, sold separately): LTF18RS, LTF18WT (Rugged Stack \/ Wild Timber) — only approved sets may be used; Damper clamp required for vented applications (NR\/PR\/NV\/PV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Design-certified to ANSI Z21.11.2 (unvented gas log heater); PFS listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTF18NE, TF18NR, TF18NV, TF18PE, TF18PR, TF18PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0023 \/ F0019 \/ F0021 \/ F0024 \/ F0020 \/ F0022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTriple-Flame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner Size\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas (N…) or Propane\/LP (P…) — by variant; not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eNE\/PE: electronic ignition with ODS pilot (battery power supply box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eNE\/PE: hand-held remote control with control module and battery power supply box included; NR\/PR: millivolt, remote-ready (thermopile wiring to optional switch); NV\/PV: variable-flame millivolt with remote receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Input (high–low)\u003c\/td\u003e\n\u003ctd\u003eTF18NE: 28,000\/24,000 Btu\/hr; TF18NR: 30,000\/21,000 Btu\/hr; TF18NV: 30,000\/21,000 Btu\/hr; TF18PE: 28,000\/24,000 Btu\/hr; TF18PR: 30,000\/24,000 Btu\/hr; TF18PV: 30,000\/24,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (ANSI Z21.11.2 unvented room heater) in masonry, UL127 factory-built fireplaces or listed vent-free fireboxes; NR\/PR manual allows vented use (bedroom\/bathroom only when installed as a vented appliance) with the damper clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Log Sets\u003c\/td\u003e\n\u003ctd\u003eLTF18RS, LTF18WT (Rugged Stack \/ Wild Timber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Opening\u003c\/td\u003e\n\u003ctd\u003e18\" log set: 19\" H × 14\" D × 28\" front W × 20\" rear W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eDesign-certified to ANSI Z21.11.2 (unvented gas log heater); PFS listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eTF18NE: 20 lb; TF18NR: 21 lb; TF18NV: 21 lb; TF18PE: 20 lb; TF18PR: 21 lb; TF18PV: 21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003eTF18NE: 22.5\" × 14\" × 8.5\"; TF18NR: 22.25\" × 14\" × 8.5\"; TF18NV: 22.25\" × 14\" × 8.5\"; TF18PE: 22.5\" × 14\" × 8.5\"; TF18PR: 22.25\" × 14\" × 8.5\"; TF18PV: 22.25\" × 14\" × 8.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBurner base assembly with grate, ODS pilot and valve; glowing embers\u003c\/li\u003e\n\u003cli\u003eHardware package and approved flexible gas hose with fittings (TF burner series)\u003c\/li\u003e\n\u003cli\u003eNE\/PE models: hand-held remote control, control module and battery power supply box\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame vent-free log set (required, sold separately): LTF18RS, LTF18WT (Rugged Stack \/ Wild Timber) — only approved sets may be used\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Damper clamp required for vented applications (NR\/PR\/NV\/PV)\u003c\/li\u003e\n\u003cli\u003eNR\/PR models: an optional wall switch, thermostat or remote may be connected (remote-ready)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Fireplace hood, damper clamp, volcanic stone, ember kits, remote\/wall controls for remote-ready models (see manual Accessories)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Natural Gas \/ Electronic Ignition","offer_id":50545796514031,"sku":"TF18NE","price":1349.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Millivolt","offer_id":50545796546799,"sku":"TF18NR","price":1019.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Variable Flame","offer_id":50545796579567,"sku":"TF18NV","price":1239.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Electronic Ignition","offer_id":50545796612335,"sku":"TF18PE","price":1349.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50545796645103,"sku":"TF18PR","price":1019.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Variable Flame","offer_id":50545796677871,"sku":"TF18PV","price":1239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Triple-Flame_Burner-1_95b14751-3065-4a04-ad19-7e299f78b6ca.jpg?v=1787051769"},{"product_id":"superior-triple-flame-24-vent-free-burner-with-ember-bed","title":"Superior Triple-Flame 24\" Vent-Free Burner with Ember Bed (for 24\"\/30\" Log Sets)","description":"\u003cp\u003eThe Superior TF2430 is a gas burner (Innovative Hearth Products). Fits LTF24RS, LTF24WT, LTF30RS, LTF30WT (Rugged Stack \/ Wild Timber).\u003c\/p\u003e\u003cp\u003eThis listing covers 6 variants — use the selectors above to choose the correct model.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e Triple-Flame vent-free log set (required, sold separately): LTF24RS, LTF24WT, LTF30RS, LTF30WT (Rugged Stack \/ Wild Timber) — only approved sets may be used; Damper clamp required for vented applications (NR\/PR\/NV\/PV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed:\u003c\/strong\u003e Design-certified to ANSI Z21.11.2 (unvented gas log heater); PFS listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTF2430NE, TF2430NR, TF2430NV, TF2430PE, TF2430PR, TF2430PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0029 \/ F0025 \/ F0027 \/ F0030 \/ F0026 \/ F0028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTriple-Flame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner Size\u003c\/td\u003e\n\u003ctd\u003e24\" \/ 30\" (one burner fits 24\" and 30\" Triple-Flame log sets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eNatural Gas (N…) or Propane\/LP (P…) — by variant; not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition\u003c\/td\u003e\n\u003ctd\u003eNE\/PE: electronic ignition with ODS pilot (battery power supply box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eNE\/PE: hand-held remote control with control module and battery power supply box included; NR\/PR: millivolt, remote-ready (thermopile wiring to optional switch); NV\/PV: variable-flame millivolt with remote receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBTU Input (high–low)\u003c\/td\u003e\n\u003ctd\u003e39,000\/28,000 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting \/ Application\u003c\/td\u003e\n\u003ctd\u003eVent-free (ANSI Z21.11.2 unvented room heater) in masonry, UL127 factory-built fireplaces or listed vent-free fireboxes; NR\/PR manual allows vented use (bedroom\/bathroom only when installed as a vented appliance) with the damper clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Log Sets\u003c\/td\u003e\n\u003ctd\u003eLTF24RS, LTF24WT, LTF30RS, LTF30WT (Rugged Stack \/ Wild Timber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Firebox Opening\u003c\/td\u003e\n\u003ctd\u003e24\" log set: 19\" H × 14\" D × 32\" front W × 22\" rear W; 30\" log set (on the 24\/30 burner): 19\" H × 14\" D × 40\" front W × 30\" rear W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eDesign-certified to ANSI Z21.11.2 (unvented gas log heater); PFS listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF11-017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003eTF2430NE: 26\" × 14.5\" × 8.5\"; TF2430NR: 26.25\" × 14\" × 8.5\"; TF2430NV: 26.25\" × 14\" × 8.5\"; TF2430PE: 26\" × 14.5\" × 8.5\"; TF2430PR: 26.25\" × 14\" × 8.5\"; TF2430PV: 26.25\" × 14\" × 8.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the product.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBurner base assembly with grate, ODS pilot and valve; glowing embers\u003c\/li\u003e\n\u003cli\u003eHardware package and approved flexible gas hose with fittings (TF burner series)\u003c\/li\u003e\n\u003cli\u003eNE\/PE models: hand-held remote control, control module and battery power supply box\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Triple-Flame vent-free log set (required, sold separately): LTF24RS, LTF24WT, LTF30RS, LTF30WT (Rugged Stack \/ Wild Timber) — only approved sets may be used\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired:\u003c\/strong\u003e Damper clamp required for vented applications (NR\/PR\/NV\/PV)\u003c\/li\u003e\n\u003cli\u003eNR\/PR models: an optional wall switch, thermostat or remote may be connected (remote-ready)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Fireplace hood, damper clamp, volcanic stone, ember kits, remote\/wall controls for remote-ready models (see manual Accessories)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Natural Gas \/ Electronic Ignition","offer_id":50545799364847,"sku":"TF2430NE","price":1419.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Millivolt","offer_id":50545799397615,"sku":"TF2430NR","price":1099.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Variable Flame","offer_id":50545799430383,"sku":"TF2430NV","price":1319.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Electronic Ignition","offer_id":50545799463151,"sku":"TF2430PE","price":1419.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Millivolt","offer_id":50545799495919,"sku":"TF2430PR","price":1099.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Variable Flame","offer_id":50545799528687,"sku":"TF2430PV","price":1319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/Triple-Flame_Burner-1_194e11ff-7af9-4100-b519-1af832730ac2.jpg?v=1787051777"}],"url":"https:\/\/hearthdepot.com\/collections\/superior-triple-flame-gas-logs.oembed","provider":"Hearth Depot","version":"1.0","type":"link"}