{"product_id":"kingsman-ob96-96-outdoor-linear-millivolt-gas-burner","title":"Kingsman OB96 96\" Outdoor Linear Millivolt Gas Burner","description":"\u003cp\u003eThe Kingsman OB96 is a 96\" linear gas burner for outdoor use, part of Kingsman's Barbara Jean Collection. It is a burner system with its own valve control, made to be built into a custom enclosure, and it is certified for USA and Canada as an outdoor decorative gas appliance. Maximum input is 156,000 BTU\/h. It has a millivolt valve and is built for natural gas.\u003c\/p\u003e\u003cp\u003eGlass media is required and sold separately. This 96\" burner takes 40 lb, at 5 lb per foot of burner: 8 bags of 5 lb. Zircon Glacier Ice is the exception: the manual calls for 50 lb of it, 10 bags. Pick the color in the required options on this page. Optional accessories listed here include a propane conversion kit and cannonballs.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This burner line also comes in 24\", 36\", 48\" and 72\". Use the size selector above to compare.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMaximum input 156,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMinimum input 110,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eControl: millivolt valve (natural gas)\u003c\/li\u003e\n\u003cli\u003eHigh and low heat settings\u003c\/li\u003e\n\u003cli\u003eSatin Coat steel, finished in high-temperature black paint\u003c\/li\u003e\n\u003cli\u003eBurners can be joined in series for a longer line of flame\u003c\/li\u003e\n\u003cli\u003eShips for natural gas; propane needs a conversion kit\u003c\/li\u003e\n\u003cli\u003eGlass media needed, sold separately: 40 lb (8 bags of 5 lb); Zircon Glacier Ice: 50 lb (10 bags of 5 lb)\u003c\/li\u003e\n\u003cli\u003eCertified for USA and Canada as an outdoor decorative gas appliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eOB96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eOB96MVN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e96 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eOutdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003e156,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003e110,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Type\u003c\/th\u003e\n\u003ctd\u003eMillivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e98 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e7 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurner Tray Height\u003c\/th\u003e\n\u003ctd\u003e2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall Height\u003c\/th\u003e\n\u003ctd\u003e4 9\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRough Opening Length\u003c\/th\u003e\n\u003ctd\u003e96 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRough Opening Width\u003c\/th\u003e\n\u003ctd\u003e5 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas inlet\u003c\/th\u003e\n\u003ctd\u003e1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eSatin Coat steel, high-temperature black paint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Media\u003c\/th\u003e\n\u003ctd\u003eNeeded, sold separately: 40 lb (8 bags of 5 lb); Zircon Glacier Ice: 50 lb (10 bags of 5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.97-2017, CSA 2.41-2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed For\u003c\/th\u003e\n\u003ctd\u003eUSA and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eBurner: 5 years. Other components (gas valves, thermocouples, igniters, lights, media): 1 year. See the manual for terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 4,500 ft the input is reduced about 4 percent per 1,000 ft, so the flame is smaller than at sea level. Have your installer or gas utility set the burner up for your elevation.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFor outdoor use only\u003c\/li\u003e\n\u003cli\u003eMinimum clearances to combustibles: side wall 24 in from the side of the burner tray; end wall 12 in from the end of the burner tray; ceiling 49 1\/2 in from the top of the burner tray; floor 8 in from the top of the burner tray\u003c\/li\u003e\n\u003cli\u003eThe valve, the ON\/OFF switch and the remote receiver (if equipped) must sit at least 5 in below the top of the burner; the clearance table allows 0 in when the OBUVM2 universal valve box is used\u003c\/li\u003e\n\u003cli\u003eOpening for the burner in a custom non-combustible enclosure: 5 3\/4 in × 96 1\/2 in\u003c\/li\u003e\n\u003cli\u003eAir openings required in a custom enclosure: 142 sq in (the manual's example is two slots of 1.5 in × 48 in)\u003c\/li\u003e\n\u003cli\u003eGlass media, needed and sold separately: 40 lb for the 96\" burner (8 bags of 5 lb); Zircon Glacier Ice: 50 lb (10 bags of 5 lb)\u003c\/li\u003e\n\u003cli\u003eSpread the glass media evenly, no higher than 1 in above the burner tray, and keep the pilot shield uncovered: covering it can cause delayed ignition\u003c\/li\u003e\n\u003cli\u003eUse the glass media listed for this burner; other glass can change how it performs and is outside the warranty\u003c\/li\u003e\n\u003cli\u003eA wind guard is recommended on outdoor burners\u003c\/li\u003e\n\u003cli\u003eFuel: ships for natural gas; propane takes the conversion kit made for this burner\u003c\/li\u003e\n\u003cli\u003eDesigned as an attended appliance. Not for use when the temperature is below freezing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Default Title","offer_id":51648063176943,"sku":"OB96MVN","price":1709.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/kingsman-w2-burners1-ae512044-1024_146bf956-548a-441d-b851-72b7edaa4ac6.jpg?v=1795645315","url":"https:\/\/hearthdepot.com\/products\/kingsman-ob96-96-outdoor-linear-millivolt-gas-burner","provider":"Hearth Depot","version":"1.0","type":"link"}