{"product_id":"kingsman-zcv34-34-clean-view-direct-vent-gas-fireplace","title":"Kingsman ZCV34 34\" Clean View Direct Vent Gas Fireplace","description":"\u003cp\u003eThe Kingsman ZCV34 is a zero-clearance 34\" clean view direct vent gas fireplace. Its maximum input is 19,000 BTU\/h on natural gas and 18,000 BTU\/h on propane. The viewing area is 28 5\/8 in wide by 25 3\/8 in high, behind tempered glass. Use the selectors above to choose the control (a millivolt valve or electronic ignition with the IPI Proflame 1 system) and the gas (natural gas or propane).\u003c\/p\u003e\u003cp\u003eKingsman's price list marks these as required for each fireplace: one fire media option (a log set or other media). The fitting choices are in the required options on this page. Optional accessories listed here include liners, accent media, venting components, remote controls, fan kits, surrounds, fuel conversion kits, installation parts, covers and heat management kits.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This fireplace line also comes in 39\" and 42\". Use the size selector above to compare.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMaximum input 19,000 BTU\/h on natural gas and 18,000 BTU\/h on propane\u003c\/li\u003e\n\u003cli\u003eViewing area 28 5\/8 in wide by 25 3\/8 in high\u003c\/li\u003e\n\u003cli\u003eControl choices: millivolt and electronic ignition (IPI Proflame 1)\u003c\/li\u003e\n\u003cli\u003eSIT valve with high\/low flame adjustment\u003c\/li\u003e\n\u003cli\u003eTempered glass front\u003c\/li\u003e\n\u003cli\u003eWall switch\u003c\/li\u003e\n\u003cli\u003eSafety screen barrier\u003c\/li\u003e\n\u003cli\u003eVented chase option: Kingsman says a vented chase keeps the walls cool to the touch and lowers mantel clearances\u003c\/li\u003e\n\u003cli\u003eListed for USA and Canada\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eZCV34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Numbers\u003c\/th\u003e\n\u003ctd\u003eZCV34N (Millivolt, Natural Gas); ZCV34LP (Millivolt, Propane); ZCV34NE (Electronic Ignition, Natural Gas); ZCV34LPE (Electronic Ignition, Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e34 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas or Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent Type\u003c\/th\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (zero clearance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 19,000 BTU\/h; Propane: 18,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 13,500 BTU\/h; Propane: 14,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Type\u003c\/th\u003e\n\u003ctd\u003eMillivolt, Electronic Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Valve\u003c\/th\u003e\n\u003ctd\u003eSIT valve with high\/low flame adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Area Width\u003c\/th\u003e\n\u003ctd\u003e28 5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Area Height\u003c\/th\u003e\n\u003ctd\u003e25 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e33 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e36 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e18 1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Width\u003c\/th\u003e\n\u003ctd\u003e33 1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Height\u003c\/th\u003e\n\u003ctd\u003e36 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Depth\u003c\/th\u003e\n\u003ctd\u003e18 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue\u003c\/th\u003e\n\u003ctd\u003e4\/7 in, sloped top flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue Position\u003c\/th\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent Pipe\u003c\/th\u003e\n\u003ctd\u003e4\/7 in flex, 4 x 6 5\/8 in hard pipe or power vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Vent Compatible\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA\/ANSI Z21.88:19, CSA 2.33:19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed For\u003c\/th\u003e\n\u003ctd\u003eUSA and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eBasic one-year warranty on component parts; limited lifetime (original owner) on the heat exchanger, combustion chamber and burner. See the manual for terms and exclusions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFraming: 33 1\/4 in wide × 36 1\/8 in high × 18 1\/8 in deep\u003c\/li\u003e\n\u003cli\u003eClearances from the installation manual, the same for a non-vented and a vented chase: front 36 in; back (from stand-offs) 0 in; side (from stand-offs) 0 in; floor 0 in; top (from stand-offs) 0 in; adjacent wall 1 1\/2 in; top of horizontal pipe 1 1\/2 in; side \u0026amp; bottom of horizontal pipe 1 in; vertical vent pipe 1 in\u003c\/li\u003e\n\u003cli\u003eNon-vented chase (fireplace installed as shipped, with the ventilation plates in place): minimum ceiling height 48 in and minimum enclosure height 48 in on natural gas and 60 in on propane, both measured from the bottom of the fireplace; top of a 90° bend inside the enclosure, at the minimum height or taller, 4 1\/2 in with the Z58WTS wall thimble shield installed\u003c\/li\u003e\n\u003cli\u003eVented chase option (the ventilation plates are removed from the top of the appliance): minimum ceiling \/ enclosure height 68 in on natural gas and 68 in on propane, measured from the bottom of the fireplace; top of a 90° bend inside the enclosure, at the minimum height or taller, 4 1\/2 in. The installation manual has the vented chase details\u003c\/li\u003e\n\u003cli\u003eRequired with the fireplace, sold separately: one fire media option (a log set or other media). The choices are in the required options on this page\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Millivolt \/ Natural Gas","offer_id":51620042014959,"sku":"ZCV34N","price":2449.99,"currency_code":"USD","in_stock":true},{"title":"Millivolt \/ Propane","offer_id":51620042047727,"sku":"ZCV34LP","price":2539.99,"currency_code":"USD","in_stock":true},{"title":"Electronic Ignition \/ Natural Gas","offer_id":51620042080495,"sku":"ZCV34NE","price":2819.99,"currency_code":"USD","in_stock":true},{"title":"Electronic Ignition \/ Propane","offer_id":51620042113263,"sku":"ZCV34LPE","price":2909.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/kingsman-zcv34-34-clean-view-direct-vent-gas-fireplace-301bd06f-1024_00c1dcfd-1a4f-4087-8564-51488a423f43.jpg?v=1795388823","url":"https:\/\/hearthdepot.com\/products\/kingsman-zcv34-34-clean-view-direct-vent-gas-fireplace","provider":"Hearth Depot","version":"1.0","type":"link"}