{"product_id":"kingsman-zcvrb72-72-linear-direct-vent-gas-fireplace","title":"Kingsman ZCVRB72 72\" Linear Direct Vent Gas Fireplace","description":"\u003cp\u003eThe Kingsman ZCVRB72 is a zero-clearance 72\" linear direct vent gas fireplace. Its maximum input is 50,000 BTU\/h. The viewing area is 73 7\/8 in wide by 20 in high, behind ceramic glass. Use the selectors above to choose the control (a millivolt valve or electronic ignition with the IPI Proflame 1 system) and the gas (natural gas or propane).\u003c\/p\u003e\u003cp\u003eOptional accessories listed here include liners, accent media, venting components, remote controls, fan kits, fuel conversion kits, covers, surrounds, installation parts, heat management kits and accent lighting.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This fireplace line also comes in 36\", 47\" and 60\". Use the size selector above to compare.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMaximum input 50,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eViewing area 73 7\/8 in wide by 20 in high\u003c\/li\u003e\n\u003cli\u003eControl choices: millivolt and electronic ignition (IPI Proflame 1)\u003c\/li\u003e\n\u003cli\u003eSIT valve with high\/low adjustment\u003c\/li\u003e\n\u003cli\u003eCeramic glass front\u003c\/li\u003e\n\u003cli\u003eHigh\/low millivolt or IPI valve system that keeps operating during power failures\u003c\/li\u003e\n\u003cli\u003eDecorative bronze glass media\u003c\/li\u003e\n\u003cli\u003eInvisiMesh safety screen\u003c\/li\u003e\n\u003cli\u003eApproved for installation in mobile homes, bedrooms and bed-sitting rooms\u003c\/li\u003e\n\u003cli\u003eListed for USA and Canada\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eZCVRB72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Numbers\u003c\/th\u003e\n\u003ctd\u003eZCVRB72N (Millivolt, Natural Gas); ZCVRB72LP (Millivolt, Propane); ZCVRB72NE (Electronic Ignition, Natural Gas); ZCVRB72LPE (Electronic Ignition, Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e72 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas or Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent Type\u003c\/th\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (zero clearance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003e50,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 34,000 BTU\/h; Propane: 39,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Type\u003c\/th\u003e\n\u003ctd\u003eMillivolt, Electronic Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Valve\u003c\/th\u003e\n\u003ctd\u003eSIT valve with high\/low adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Area Width\u003c\/th\u003e\n\u003ctd\u003e73 7\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Area Height\u003c\/th\u003e\n\u003ctd\u003e20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Width\u003c\/th\u003e\n\u003ctd\u003e73 1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Height\u003c\/th\u003e\n\u003ctd\u003e17 7\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e78 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e40 5\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e19 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Width\u003c\/th\u003e\n\u003ctd\u003e79 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Height\u003c\/th\u003e\n\u003ctd\u003e42 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Depth\u003c\/th\u003e\n\u003ctd\u003e19 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue\u003c\/th\u003e\n\u003ctd\u003e5\/8 in, top flue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue Position\u003c\/th\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent Pipe\u003c\/th\u003e\n\u003ctd\u003e5\/8 in flex or hard pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Vent Compatible\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListed For\u003c\/th\u003e\n\u003ctd\u003eUSA and Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eBasic one-year warranty on component parts; limited lifetime (original owner) on the heat exchanger, combustion chamber and burner. See the manual for terms and exclusions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLinear burner\u003c\/li\u003e\n\u003cli\u003eBronze glass media: 3 bags (15 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFraming: 79 1\/8 in wide × 42 in high × 19 in deep\u003c\/li\u003e\n\u003cli\u003eClearances from the installation manual: front 36 in; back (from stand-offs) 0 in; side (from stand-offs) 0 in; floor 0 in; minimum ceiling height, measured from the fireplace bottom, 79 in; top (from stand-offs) 0 in; top of horizontal pipe 2 in; side \u0026amp; bottom of horizontal pipe 1 in; vertical vent pipe 1 in\u003c\/li\u003e\n\u003cli\u003eVented chase option: minimum enclosure height 79 in, with a minimum of 285 sq in of ventilation; before the fireplace is installed, the inner and outer ventilation plates are removed and reinstalled in a vertical position, and once the plates are converted the chase must be vented. The installation manual has the vented chase details\u003c\/li\u003e\n\u003cli\u003eWith ICC\/Excel hard pipe, a starter piece of M\u0026amp;G DuraVent is used at the fireplace flue\u003c\/li\u003e\n\u003cli\u003eApproved for installation in mobile homes, bedrooms and bed-sitting rooms\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingsman","offers":[{"title":"Millivolt \/ Natural Gas","offer_id":51620041228527,"sku":"ZCVRB72N","price":8939.99,"currency_code":"USD","in_stock":true},{"title":"Millivolt \/ Propane","offer_id":51620041261295,"sku":"ZCVRB72LP","price":9019.99,"currency_code":"USD","in_stock":true},{"title":"Electronic Ignition \/ Natural Gas","offer_id":51620041294063,"sku":"ZCVRB72NE","price":9289.99,"currency_code":"USD","in_stock":true},{"title":"Electronic Ignition \/ Propane","offer_id":51620041326831,"sku":"ZCVRB72LPE","price":9359.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/kingsman-zcvrb47-47-linear-direct-vent-gas-fireplace-10af2391-1024_f289064b-17ff-4ecb-87f4-1f115615e52e.jpg?v=1795388817","url":"https:\/\/hearthdepot.com\/products\/kingsman-zcvrb72-72-linear-direct-vent-gas-fireplace","provider":"Hearth Depot","version":"1.0","type":"link"}