{"product_id":"monessen-artisan-48-vent-free-linear-gas-fireplace","title":"Monessen Artisan 48\" Vent-Free Linear Gas Fireplace","description":"\u003cp\u003eThe Monessen Artisan 48\" is a vent-free linear gas fireplace with IntelliFire Touch ignition. Its flames rise through Diamond fire glass in front of reflective black glass panels, with multicolor LED lighting under the glass. It is built for natural gas or propane. Maximum input: 39,000 BTU\/h (Natural Gas) and 38,000 BTU\/h (Propane). Nothing else is needed to complete it: the fire glass is included.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This fireplace also comes in 42\", 60\" and 72\". Use the size selector above to compare.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLinear vent-free design with IntelliFire Touch ignition\u003c\/li\u003e\n\u003cli\u003eFlames rise through Diamond fire glass; four bags are supplied\u003c\/li\u003e\n\u003cli\u003eReflective black glass panels inside the firebox multiply the flame\u003c\/li\u003e\n\u003cli\u003eMulticolor LED lighting under the glass, set from the included remote: on\/off, colour and intensity\u003c\/li\u003e\n\u003cli\u003eIFT2-RC450 remote included; it also raises and lowers the flame\u003c\/li\u003e\n\u003cli\u003eFactory-installed battery pack keeps the flame available in a power outage (four AA cells, not included); lights and other 110-120 VAC functions stop on battery\u003c\/li\u003e\n\u003cli\u003eSafety timer: when the remote or wall switch sends no command during 9 hours of continuous burning, the burner shuts down\u003c\/li\u003e\n\u003cli\u003eRated 99.9% efficient\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured (mobile) homes where local codes allow\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eAVFL48NIF (Natural Gas); AVFL48PIF (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas or Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eVent-Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 39,000 BTU\/h; Propane: 38,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 27,500 BTU\/h; Propane: 31,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e52 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e39 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e13 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBack Width\u003c\/th\u003e\n\u003ctd\u003e52 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Width\u003c\/th\u003e\n\u003ctd\u003e48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Height\u003c\/th\u003e\n\u003ctd\u003e17 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Width\u003c\/th\u003e\n\u003ctd\u003e52 5\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Height\u003c\/th\u003e\n\u003ctd\u003e39 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Depth\u003c\/th\u003e\n\u003ctd\u003e13 1\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e220 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Inlet Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 5.0 to 10.0 in w.c.; Propane: 11.0 to 13.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 3.5 in w.c.; Propane: 10.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e110-120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented heaters); CSA design certified; UL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eHHT limited warranty - firebox and heat exchanger: 20 years parts, 3 years labor; burners, logs and refractory components of fireplaces: 10 years parts, 1 year labor; vent-free burners and logs: 5 years; electrical components (modules, remotes, valves, pilots, blowers, lights): 2 years; cement refractory and glass liner panels: 2 years; other parts: 1 year. Conditions and exclusions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTwo anchoring screws\u003c\/li\u003e\n\u003cli\u003eFour bags of Diamond fire glass media\u003c\/li\u003e\n\u003cli\u003eReflective black glass panels (back and two sides)\u003c\/li\u003e\n\u003cli\u003eMulticolor LED light strips\u003c\/li\u003e\n\u003cli\u003eIFT2-RC450 remote control\u003c\/li\u003e\n\u003cli\u003eAir deflector glass\u003c\/li\u003e\n\u003cli\u003eNon-combustible board for the facing above the opening\u003c\/li\u003e\n\u003cli\u003eBattery pack for backup power (batteries not included)\u003c\/li\u003e\n\u003cli\u003eInstallation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhere vent-free is allowed:\u003c\/strong\u003e we do not ship vent-free gas appliances to California, Minnesota, New York City or Canada. Massachusetts allows them only with a licensed plumber or gas fitter, a permit and inspection, and a carbon monoxide detector, and never in a bedroom or bathroom. Cities and counties can add their own rules, so check with your local building department before you order. Full details are in our \u003ca href=\"\/pages\/vent-free-sales-policy\"\u003eVent-Free Sales Policy\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced about 4 percent per 1,000 ft by fitting a smaller burner orifice, so the flame is smaller than at sea level. Your installer or gas utility sizes the orifice.\u003c\/p\u003e\u003cp\u003eOptional accessories for it include log kits, trim kits, fronts and doors, fire glass colours, remotes and controls and accent media.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNot for bedrooms or bathrooms: the manufacturer does not allow installation in either room.\u003c\/li\u003e\n\u003cli\u003eSupplemental heat: it is tested as a supplemental room heater or decorative appliance, not as the main heating system of a home.\u003c\/li\u003e\n\u003cli\u003eGas type is set at the factory: order the natural gas or the propane version. Field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003eRoom size: a vent-free heater needs enough air. The National Fuel Gas Code treats a room as a confined space when it has less than 50 cubic feet of volume for every thousand BTU per hour of all gas appliances in it. A confined or unusually tight room needs added combustion and ventilation air. Your installer checks the room against this.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances to combustibles: 36 in to the ceiling and 6 in to a side wall.\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other flammable objects at least 36 in from the front.\u003c\/li\u003e\n\u003cli\u003eIt can be placed against a combustible back wall.\u003c\/li\u003e\n\u003cli\u003eMantel clearances depend on the mantel depth; follow the mantel chart in the installation manual.\u003c\/li\u003e\n\u003cli\u003eIt may stand on a combustible floor, or on a raised platform, as long as the surface is hard (wood, plywood or particle board): no carpet, vinyl, tile or other soft floor coverings.\u003c\/li\u003e\n\u003cli\u003eWhere vinyl flooring runs up to the wall, a hearth extension at least 14 in deep is recommended.\u003c\/li\u003e\n\u003cli\u003eAbove the opening, non-combustible facing at least 7 1\/4 in high and as wide as the appliance is needed; a non-combustible board for it is supplied.\u003c\/li\u003e\n\u003cli\u003eTwo finishing methods are approved: drywall flush with the face on the left, right and bottom with the supplied board above, or the fireplace recessed behind non-combustible facing that stops at the opening. The second method is the one to use with the optional fronts and trim kits.\u003c\/li\u003e\n\u003cli\u003eFinishing materials on the floor, walls and mantel must withstand temperatures up to 190°F.\u003c\/li\u003e\n\u003cli\u003eGas only: never burn wood or other solid fuel in it.\u003c\/li\u003e\n\u003cli\u003eElectrical: the junction box is wired to an unswitched 110-120 VAC circuit (GFCI protected where code calls for it, for example near a sink).\u003c\/li\u003e\n\u003cli\u003ePropane models need an external regulator that holds supply pressure to no more than 13 in w.c.\u003c\/li\u003e\n\u003cli\u003eGas connection: 1\/2 in NPT at the manual shutoff valve; the gas line enters through the left side or the bottom (there is no access on the right).\u003c\/li\u003e\n\u003cli\u003eUse only the amount of glass media supplied: extra glass can starve the burner of air and cause sooting.\u003c\/li\u003e\n\u003cli\u003eThe optional stone kit and the optional driftwood log kit are used one at a time, never together.\u003c\/li\u003e\n\u003cli\u003eWith the optional driftwood log kit, one log of the kit is not used in this size.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCare \u0026amp; Maintenance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFirst use: run the burner on high for three to four hours with the room well ventilated.\u003c\/li\u003e\n\u003cli\u003eHave a qualified service technician inspect it before first use and at least once a year.\u003c\/li\u003e\n\u003cli\u003eClean more often where lint from carpet or bedding builds up.\u003c\/li\u003e\n\u003cli\u003eCheck the remote each season and replace its batteries.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Monessen","offers":[{"title":"Natural Gas","offer_id":51637244035311,"sku":"AVFL48NIF","price":4219.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":51637244068079,"sku":"AVFL48PIF","price":4219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/monessen-artisan-48-vent-free-linear-gas-fireplace-32fec91f-1024_f3acc9c2-481d-4629-8bec-45def22ac158.jpg?v=1795533822","url":"https:\/\/hearthdepot.com\/products\/monessen-artisan-48-vent-free-linear-gas-fireplace","provider":"Hearth Depot","version":"1.0","type":"link"}