{"product_id":"monessen-glow-getter-24-vent-free-gas-burner-burner-only","title":"Monessen Glow Getter 24\" Vent-Free Gas Burner (Burner Only)","description":"\u003cp\u003eThe Monessen Glow Getter 24\" is a vent-free gas log burner. This listing is the burner only: a log set is required to run it and is sold separately. It takes a 24\" or 30\" Charisma, Dynamo or Moxie log set. You choose millivolt or IntelliFire Plus intermittent pilot (IPI) control, in natural gas or propane. Maximum input: 37,000 BTU\/h (Natural Gas) and 36,000 BTU\/h (Propane). It is dual rated, for vent-free or vented use.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This burner also comes in 18\". Use the size selector above to compare.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGlow Getter burner: multi-peak flames over an active, glowing ember bed\u003c\/li\u003e\n\u003cli\u003eSold with millivolt control or IntelliFire Plus intermittent pilot (IPI) ignition\u003c\/li\u003e\n\u003cli\u003eIntelliFire Plus (IPI) models include a remote control\u003c\/li\u003e\n\u003cli\u003eIntelliFire Plus (IPI) models run from a built-in battery pack (four AA batteries); no household power is needed\u003c\/li\u003e\n\u003cli\u003eMillivolt models are self-powered and need no household electricity\u003c\/li\u003e\n\u003cli\u003eIPI models: when the remote sends no command during 9 hours of continuous burning, the burner shuts down\u003c\/li\u003e\n\u003cli\u003eOxygen depletion sensor (ODS) pilot shuts the gas off if the oxygen level in the room starts to drop\u003c\/li\u003e\n\u003cli\u003eRated 99% efficient\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured (mobile) homes where local codes allow\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eGG24NV-B (Millivolt, Natural Gas); GG24PV-B (Millivolt, Propane); GG24NIF-B (Intermittent Pilot, Natural Gas); GG24PIF-B (Intermittent Pilot, Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas or Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003eMillivolt or Intermittent Pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eVent-Free (dual rated: can also be installed vented)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Log Sets\u003c\/th\u003e\n\u003ctd\u003eCharisma, Dynamo and Moxie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 37,000 BTU\/h; Propane: 36,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 26,000 BTU\/h; Propane: 27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Inlet Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 5.0 to 10.0 in w.c.; Propane: 11.0 to 13.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 3.5 in w.c.; Propane: 10.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Front Width (24 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e33.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Back Width (24 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e26.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Depth (24 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e14.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Height (24 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Front Width (24 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e31.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Back Width (24 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e24.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Depth (24 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e14.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Height (24 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Front Width (30 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e36.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Back Width (30 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e29.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Depth (30 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e14.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Height (30 in Dynamo logs)\u003c\/th\u003e\n\u003ctd\u003e20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Front Width (30 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e34.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Back Width (30 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e27.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Depth (30 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e14.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Firebox Height (30 in Moxie or Charisma logs)\u003c\/th\u003e\n\u003ctd\u003e20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented heaters); ANSI Z21.60 \/ CSA 2.26 (vented decorative gas appliance, U.S. only); CSA design certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eHHT limited warranty - vent-free burners and logs: 5 years; electrical components (modules, remotes, valves, pilots, blowers, lights): 2 years; other parts: 1 year. Conditions and exclusions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eGrate and cover assembly that positions the logs\u003c\/li\u003e\n\u003cli\u003eOne bag of lava rock and one bag of rock wool\u003c\/li\u003e\n\u003cli\u003eEmber bed log switch\u003c\/li\u003e\n\u003cli\u003eOn\/off switch and wire harness\u003c\/li\u003e\n\u003cli\u003eRemote control (IPI models only)\u003c\/li\u003e\n\u003cli\u003eDamper stop\u003c\/li\u003e\n\u003cli\u003eFlex line and pipe fittings\u003c\/li\u003e\n\u003cli\u003eTwo anchor screws\u003c\/li\u003e\n\u003cli\u003eInstallation and owner's manual\u003c\/li\u003e\n\u003cli\u003eLog set: not included, sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhere vent-free is allowed:\u003c\/strong\u003e we do not ship vent-free gas appliances to California, Minnesota, New York City or Canada. Massachusetts allows them only with a licensed plumber or gas fitter, a permit and inspection, and a carbon monoxide detector, and never in a bedroom or bathroom. Cities and counties can add their own rules, so check with your local building department before you order. Full details are in our \u003ca href=\"\/pages\/vent-free-sales-policy\"\u003eVent-Free Sales Policy\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e above 2,000 ft the input is reduced about 4 percent per 1,000 ft, so the flame is smaller than at sea level. Have your installer or gas utility set the burner up for your elevation.\u003c\/p\u003e\u003cp\u003eRequired to complete the installation and sold separately: a log set. Choose it in the options on this page. The burner must not be run without a log set in place. Optional accessories for it include remotes and controls, a canopy hood, installation parts and accent media.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNot for bedrooms or bathrooms: the manufacturer does not allow installation in either room.\u003c\/li\u003e\n\u003cli\u003eSupplemental heat: it is tested as a supplemental room heater or decorative appliance, not as the main heating system of a home.\u003c\/li\u003e\n\u003cli\u003eGas type is set at the factory: order the natural gas or the propane version. Field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003eRoom size: a vent-free heater needs enough air. The National Fuel Gas Code treats a room as a confined space when it has less than 50 cubic feet of volume for every thousand BTU per hour of all gas appliances in it. Your installer checks the room against this.\u003c\/li\u003e\n\u003cli\u003eWhere it installs: in a fireplace or in a listed vent-free firebox enclosure (CSA\/ANSI Z21.91) that meets the minimum dimensions in the specifications. It may not go into a factory-built fireplace whose instructions rule out unvented gas logs.\u003c\/li\u003e\n\u003cli\u003eVented option: the burner is dual rated, so it can also run as a vented gas log set with the chimney damper fixed open; that calls for damper clamps.\u003c\/li\u003e\n\u003cli\u003eIf the vent-free clearances cannot be met, it must be run vented, with the chimney damper open.\u003c\/li\u003e\n\u003cli\u003eA damper stop is included; it is fitted so that the fireplace damper can never close fully.\u003c\/li\u003e\n\u003cli\u003eIn Massachusetts, a vented installation needs the damper permanently removed or welded fully open.\u003c\/li\u003e\n\u003cli\u003eA thermostat control may be used in vent-free installations only.\u003c\/li\u003e\n\u003cli\u003eIf the fireplace has glass doors, they stay open whenever the burner runs.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer advises against any barrier larger than 3 in in front of the logs.\u003c\/li\u003e\n\u003cli\u003eAbove the fireplace opening the facing must be non-combustible: with 12 in or more of it no hood is needed, from 8 in to 12 in the optional hood is needed, and less than 8 in is not allowed.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances to combustibles: 42 in to the ceiling and 9 in to a side wall.\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other flammable objects at least 3 ft from the front.\u003c\/li\u003e\n\u003cli\u003eMantel clearances depend on the mantel depth and on whether a hood is fitted; follow the mantel chart in the installation manual.\u003c\/li\u003e\n\u003cli\u003eWhere vinyl flooring runs up to the wall, a hearth extension at least 14 in deep is recommended.\u003c\/li\u003e\n\u003cli\u003eWhere the gas supply pressure is above the maximum inlet pressure in the specifications, an external regulator is needed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCare \u0026amp; Maintenance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHave a qualified service technician inspect it before first use and at least once a year.\u003c\/li\u003e\n\u003cli\u003eBefore installation, and every year afterwards, have a professional clean the chimney and the fireplace floor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Monessen","offers":[{"title":"Millivolt \/ Natural Gas","offer_id":51637245870319,"sku":"GG24NV-B","price":869.0,"currency_code":"USD","in_stock":true},{"title":"Millivolt \/ Propane","offer_id":51637245903087,"sku":"GG24PV-B","price":869.0,"currency_code":"USD","in_stock":true},{"title":"Intermittent Pilot \/ Natural Gas","offer_id":51637245935855,"sku":"GG24NIF-B","price":1209.0,"currency_code":"USD","in_stock":true},{"title":"Intermittent Pilot \/ Propane","offer_id":51637245968623,"sku":"GG24PIF-B","price":1209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/monessen-burner-glow-getter-24-vent-free-gas-burner-burner-only-ref-1024_c938c1ed-7a8e-4db3-acaf-2b0c0117e096.jpg?v=1795533920","url":"https:\/\/hearthdepot.com\/products\/monessen-glow-getter-24-vent-free-gas-burner-burner-only","provider":"Hearth Depot","version":"1.0","type":"link"}