{"product_id":"monessen-symphony-32-vent-free-gas-fireplace","title":"Monessen Symphony 32\" Vent-Free Gas Fireplace","description":"\u003cp\u003eThe Monessen Symphony 32\" is a slim, clean-face vent-free gas fireplace that arrives with the Natural Blaze burner system and a seven-piece refractory cement log set, so no separate log purchase is needed. It needs no chimney or vent. You choose millivolt or intermittent pilot (IPI) control, in natural gas or propane. Maximum input: 28,000 BTU\/h (Natural Gas) and 27,000 BTU\/h (Propane).\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNatural Blaze burner system\u003c\/li\u003e\n\u003cli\u003eSlim, clean-face design\u003c\/li\u003e\n\u003cli\u003eSeven-piece refractory cement log set included\u003c\/li\u003e\n\u003cli\u003eSold with millivolt or intermittent pilot (IPI) control\u003c\/li\u003e\n\u003cli\u003eMillivolt models are self-powered and need no household electricity; a piezo igniter lights the pilot without matches or batteries\u003c\/li\u003e\n\u003cli\u003eIntermittent pilot (IPI) models power their 6-volt control from the fireplace junction box, with battery back-up for on\/off operation of about 48 hours in an outage\u003c\/li\u003e\n\u003cli\u003eIPI models have a cold-climate switch that keeps a standing pilot lit\u003c\/li\u003e\n\u003cli\u003eMillivolt models: variable low-to-high flame height control\u003c\/li\u003e\n\u003cli\u003eIPI models: flame height adjustment needs an optional stepper motor kit with RF receiver\u003c\/li\u003e\n\u003cli\u003eOxygen depletion sensor (ODS) pilot shuts the gas off if the oxygen level in the room starts to drop\u003c\/li\u003e\n\u003cli\u003eEasy-access control panel\u003c\/li\u003e\n\u003cli\u003eApproved for manufactured (mobile) homes where local codes allow\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eVFC32LNV (Millivolt, Natural Gas); VFC32LPV (Millivolt, Propane); VFC32LNI (Intermittent Pilot, Natural Gas); VFC32LPI (Intermittent Pilot, Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel Type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas or Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003eMillivolt or Intermittent Pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eVent-Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 28,000 BTU\/h; Propane: 27,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Input\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 19,000 BTU\/h; Propane: 22,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Size\u003c\/th\u003e\n\u003ctd\u003e32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e30 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e14 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBack Width\u003c\/th\u003e\n\u003ctd\u003e25 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Width\u003c\/th\u003e\n\u003ctd\u003e28 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Height\u003c\/th\u003e\n\u003ctd\u003e19 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Width\u003c\/th\u003e\n\u003ctd\u003e32 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Height\u003c\/th\u003e\n\u003ctd\u003e30 1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming Depth\u003c\/th\u003e\n\u003ctd\u003e13 3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eMillivolt, Natural Gas: 55 lb; Millivolt, Propane: 58 lb; Intermittent Pilot: 78 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Inlet Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 5.0 to 10.0 in w.c.; Propane: 11.0 to 13.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold Pressure\u003c\/th\u003e\n\u003ctd\u003eNatural Gas: 3.5 in w.c.; Propane: 10.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 V, 60 Hz, 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eANSI Z21.11.2 (unvented heaters); CSA design certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eHHT limited warranty - firebox and heat exchanger: 20 years parts, 3 years labor; burners, logs and refractory components of fireplaces: 10 years parts, 1 year labor; vent-free burners and logs: 5 years; electrical components (modules, remotes, valves, pilots, blowers, lights): 2 years; cement refractory and glass liner panels: 2 years; other parts: 1 year; replacement parts and optional accessories: 1 year on parts, no labor coverage. Conditions and exclusions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNatural Blaze burner system\u003c\/li\u003e\n\u003cli\u003eSeven-piece refractory cement log set\u003c\/li\u003e\n\u003cli\u003eGas flex line with shut-off valve\u003c\/li\u003e\n\u003cli\u003eCanopy with mounting screws\u003c\/li\u003e\n\u003cli\u003eTwo anchoring screws\u003c\/li\u003e\n\u003cli\u003eInstallation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhere vent-free is allowed:\u003c\/strong\u003e we do not ship vent-free gas appliances to California, Minnesota, New York City or Canada. Massachusetts allows them only with a licensed plumber or gas fitter, a permit and inspection, and a carbon monoxide detector, and never in a bedroom or bathroom. Cities and counties can add their own rules, so check with your local building department before you order. Full details are in our \u003ca href=\"\/pages\/vent-free-sales-policy\"\u003eVent-Free Sales Policy\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh altitude:\u003c\/strong\u003e input ratings apply up to 2,000 ft. Above 2,000 ft the input is reduced 4 percent for each 1,000 ft above sea level, so the flame is smaller than at sea level. Have your installer or gas supplier set the appliance up for your elevation.\u003c\/p\u003e\u003cp\u003eOptional accessories for it include firebox liners, trim kits, fronts and doors, a blower and remotes and controls.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNot for bedrooms or bathrooms: the manufacturer does not allow installation in either room.\u003c\/li\u003e\n\u003cli\u003eSupplemental heat: it is tested as a supplemental room heater or decorative appliance, not as the main heating system of a home.\u003c\/li\u003e\n\u003cli\u003eGas type is set at the factory: order the natural gas or the propane version. Field conversion is not permitted.\u003c\/li\u003e\n\u003cli\u003eRoom size: a vent-free heater needs enough air. The National Fuel Gas Code treats a room as a confined space when it has less than 50 cubic feet of volume for every thousand BTU per hour of all gas appliances in it. Your installer checks the room against this.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances to combustibles: 42 in to the ceiling and 9 in to a side wall.\u003c\/li\u003e\n\u003cli\u003eKeep curtains, furniture, clothing and other flammable objects at least 42 in from the front.\u003c\/li\u003e\n\u003cli\u003eIt can be placed against a combustible back wall.\u003c\/li\u003e\n\u003cli\u003eMantel: the lowest combustible mantel height on the manufacturer's chart is 10 in; deeper mantels must sit higher.\u003c\/li\u003e\n\u003cli\u003eWhere vinyl flooring runs up to the wall, a hearth extension at least 14 in deep is recommended.\u003c\/li\u003e\n\u003cli\u003eInstall the canopy that comes with the unit; it is not optional.\u003c\/li\u003e\n\u003cli\u003eAn optional blower and its wiring go in before the fireplace is framed and enclosed.\u003c\/li\u003e\n\u003cli\u003ePropane models need an external regulator that holds supply pressure to no more than 13 in w.c.\u003c\/li\u003e\n\u003cli\u003eBurn it only with its own Monessen logs and the rock wool supplied; no other media on the burner.\u003c\/li\u003e\n\u003cli\u003eOptional volcanic rock goes on the firebox floor only.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCare \u0026amp; Maintenance\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eHave a qualified service technician inspect it before first use and at least once a year.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Monessen","offers":[{"title":"Millivolt \/ Natural Gas","offer_id":51637243642095,"sku":"VFC32LNV","price":1859.0,"currency_code":"USD","in_stock":true},{"title":"Millivolt \/ Propane","offer_id":51637243674863,"sku":"VFC32LPV","price":1859.0,"currency_code":"USD","in_stock":true},{"title":"Intermittent Pilot \/ Natural Gas","offer_id":51637243707631,"sku":"VFC32LNI","price":1939.0,"currency_code":"USD","in_stock":true},{"title":"Intermittent Pilot \/ Propane","offer_id":51637243740399,"sku":"VFC32LPI","price":1939.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/monessen-symphony-32-vent-free-gas-fireplace-1a91763b-1024_84e12356-6871-4c5d-842d-29c5f8f9f67a.jpg?v=1795533803","url":"https:\/\/hearthdepot.com\/products\/monessen-symphony-32-vent-free-gas-fireplace","provider":"Hearth Depot","version":"1.0","type":"link"}