{"product_id":"superior-wct2042-42-louvered-wood-burning-fireplace","title":"Superior WCT2000 42\" Louvered Wood Burning Fireplace (WCT2042)","description":"\u003cp\u003eThe Superior WCT2042WSI is a 42\" wood-burning fireplace in Superior's Merit Series (Innovative Hearth Products). It offers a 42\" × 21-1\/2\" opening, with a 28-1\/2\" installed depth.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNeed a different size? This series is also available in 36\" — use the size selector above to compare all sizes.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChimney \/ venting:\u003c\/strong\u003e Wood-burning chimney — IHP 8DM standard or 8HT hi-temp double-wall snap-lock chimney (8HT required in Canada).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower:\u003c\/strong\u003e Optional variable-speed blower kit BK (circulating models only); pre-wired receptacle supplied, 120 V field wiring by installer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired to complete:\u003c\/strong\u003e chimney system and hearth extension (sold separately, choose from the options on this page) — see Installation \u0026amp; Planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e 28-1\/2\" depth, hearth extension required (not included): 66\" × 20\" minimum — 20\" in front of and 12\" beyond each side of the opening; non-combustible (k ≤ 0.84) with galvanized ember protector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety listed:\u003c\/strong\u003e Tested and listed by PFS Corporation to UL 127 \/ ULC-S610 as a factory-built fireplace; approved for vented (ANSI Z21.60, Z21.84) or vent-free (ANSI Z21.11.2) gas log sets (report F09-171 (PFS)).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWCT2042WSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Numbers\u003c\/td\u003e\n\u003ctd\u003eF0690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMerit Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Style\u003c\/td\u003e\n\u003ctd\u003eCirculating (louvered) traditional wood-burning fireplace — rolled-louver face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eWood-Burning Fireplace (factory-built, UL 127 \/ ULC-S610)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Size\u003c\/td\u003e\n\u003ctd\u003e42\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eSolid wood or processed solid-fuel fire logs; may also accept a vented gas log set (ANSI Z21.60 \/ Z21.84) or a vent-free gas log heater (ANSI Z21.11.2) with the required IHP hood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eIndoor built-in (framed) installation; approved for aftermarket permanently located manufactured homes (USA) and mobile homes where not prohibited by local codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting Type\u003c\/td\u003e\n\u003ctd\u003eWood-burning chimney — IHP 8DM standard or 8HT hi-temp double-wall snap-lock chimney (8HT required in Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace Opening (W × H)\u003c\/td\u003e\n\u003ctd\u003e42\" × 21-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Firebox — Front Width\u003c\/td\u003e\n\u003ctd\u003e38-7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Firebox — Rear Width\u003c\/td\u003e\n\u003ctd\u003e25-3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Firebox — Height\u003c\/td\u003e\n\u003ctd\u003e21-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior Firebox — Depth\u003c\/td\u003e\n\u003ctd\u003e14-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Width\u003c\/td\u003e\n\u003ctd\u003e44\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Height\u003c\/td\u003e\n\u003ctd\u003e37-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Depth\u003c\/td\u003e\n\u003ctd\u003e28-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior\u003c\/td\u003e\n\u003ctd\u003eFully insulated firebox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefractory \/ Liner\u003c\/td\u003e\n\u003ctd\u003eWhite stacked refractory panels (WS) — sides, rear and bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eOptional variable-speed blower kit BK (circulating models only); pre-wired receptacle supplied, 120 V field wiring by installer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eTextured powder-coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eTested and listed by PFS Corporation to UL 127 \/ ULC-S610 as a factory-built fireplace; approved for vented (ANSI Z21.60, Z21.84) or vent-free (ANSI Z21.11.2) gas log sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing Report No.\u003c\/td\u003e\n\u003ctd\u003eF09-171 (PFS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping Information\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e180 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e46\" × 22\" × 37.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Volume\u003c\/td\u003e\n\u003ctd\u003e22 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eShipping figures describe the packed carton, not the installed fireplace.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhat's Included\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStacked white refractory panels (sides, rear, bottom) and refractory hearth\u003c\/li\u003e\n\u003cli\u003eLog grate\u003c\/li\u003e\n\u003cli\u003eMesh fire screens\u003c\/li\u003e\n\u003cli\u003eAdjustable outside-air damper\u003c\/li\u003e\n\u003cli\u003eInstallation and operation manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eInstallation \u0026amp; Planning\u003c\/h2\u003e\u003ch3\u003eFraming \u0026amp; Installation Dimensions\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming Width (minimum opening)\u003c\/td\u003e\n\u003ctd\u003e44-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming Height\u003c\/td\u003e\n\u003ctd\u003e37-5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming Depth\u003c\/td\u003e\n\u003ctd\u003e22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside Air\u003c\/td\u003e\n\u003ctd\u003eOptional outside air kit AK4 (sidewall) \/ AK4F (floor) — knockout provided; combustion-air duct must not terminate in an attic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Line Access\u003c\/td\u003e\n\u003ctd\u003e1\/2\" black iron pipe through the rear gas-line conduit sleeve (knockout on either side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHearth Extension\u003c\/td\u003e\n\u003ctd\u003eRequired (not included): 66\" × 20\" minimum — 20\" in front of and 12\" beyond each side of the opening; non-combustible (k ≤ 0.84) with galvanized ember protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eClearances to Combustibles\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack\u003c\/td\u003e\n\u003ctd\u003e3\/4\" air space to combustibles (not required at nailing flanges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSides\u003c\/td\u003e\n\u003ctd\u003e3\/4\" air space to combustibles (not required at nailing flanges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney Pipe Clearance\u003c\/td\u003e\n\u003ctd\u003e1\" air space to the chimney outer pipe surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop Standoffs\u003c\/td\u003e\n\u003ctd\u003e0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor\u003c\/td\u003e\n\u003ctd\u003e0\" — on carpet, tile or other combustible flooring (other than wood) the fireplace must sit on a metal or wood panel the full width and depth of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible Side Wall\u003c\/td\u003e\n\u003ctd\u003e12\" minimum from the opening to a perpendicular combustible wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible Mantel\u003c\/td\u003e\n\u003ctd\u003eCombustible trim\/mantel projecting from the face: not within 12\" of the opening (9\" of the top louver opening on louvered models); projections over 1-1\/2\" must be at least 12\" above the opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustible Material Restrictions\u003c\/td\u003e\n\u003ctd\u003eNo combustible material on the fireplace face or below the top spacers; do not pack the required air spaces with insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eRequired Components \u0026amp; Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChimney system (required, sold separately):\u003c\/strong\u003e IHP 8DM standard or 8HT hi-temp snap-lock double-wall chimney sections, firestop spacer, roof flashing, storm collar and an approved termination; 8HT required in Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHearth extension (required, not included):\u003c\/strong\u003e non-combustible, sized per the clearance table, with galvanized ember protector\u003c\/li\u003e\n\u003cli\u003eVent-free gas log heater use requires the IHP adjustable hood GA6050 (sold separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional:\u003c\/strong\u003e Bi-fold glass doors (36\": BDB36 black \/ BDB36B brass \/ BDB36P platinum), outside air kits AK4 \/ AK4F, vented or vent-free gas log sets, refractory stain kits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Superior Fireplaces","offers":[{"title":"Default Title","offer_id":50497403519215,"sku":"WCT2042WSI","price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5633\/8415\/files\/WRT_WCT2000-2_03d85614-3161-44fc-80ed-72686b7e8b21.jpg?v=1786631363","url":"https:\/\/hearthdepot.com\/products\/superior-wct2042-42-louvered-wood-burning-fireplace","provider":"Hearth Depot","version":"1.0","type":"link"}