VFSM18NAT

Empire Slope Glaze 18" Vent-Free Gas Burner

★★★★★ (0)

Size: 18"

Control Type: Manual
Fuel Type: Natural Gas
No sales tax at checkout* *Outside Wyoming. See your estimate →
How this estimate works

One selected item; excludes shipping, accessories and discounts. Actual rates vary by address and retailer. This is not a competitor quote. Use tax may still be due even when we do not collect sales tax. Final charges are shown at checkout.

Rates: Tax Foundation, July 1, 2026
Free shipping over $200Contiguous US · large items arrive curbside, liftgate included
Ships in 3–6 business daysIn-stock items · tracking emailed when it ships
Save 3% with Zelle or wire transferOn top of any other discount · choose it at checkout
Not sure what fits? Talk to a hearth expert(888) 398-1887 · Mon–Sat 8am–8pm ET · or start a live chat

Required for installation — choose one, or confirm you already have one

Log Set Required — choose one

Recommended

Remote & Controls

By placing an order at HearthDepot (https://hearthdepot.com/) you declare that you have read and accept this Shipping & Delivery Policy.

Order Confirmation

As soon as you place your order, you will receive a confirmation email. After that, we will process your order within 1–2 business days, during which time we will verify that all items ordered are in stock and available for immediate shipment. If your order is available for delivery within the advertised time frame, we will submit it to the warehouse for shipment. If the expected delivery time exceeds the advertised time frame, we will reach out to you via email and/or phone to confirm the order.

Shipping Costs

  • Free standard shipping on orders over $200 (contiguous US).
  • Orders of $199.99 or less: a flat $49 shipping & handling fee (contiguous US).
  • Alaska, Hawaii & Puerto Rico: a flat $500 non-contiguous delivery fee per order, with delivery typically taking 5–20 business days. Contact us before ordering if you would like to confirm the delivery time for your specific address.

Estimated Time of Shipping

Our standard shipping-out time for in-stock orders is 4–12 business days, and most orders ship within approximately 3–6 business days of placing the order. Made-to-order and built-to-order products (including many Empire Comfort Systems fireplaces manufactured to your configuration) typically ship within 4–12 weeks; the estimated lead time is indicated on the product page. If the expected shipping date for your order would fall outside the advertised time frame, our customer service team will reach out to confirm that the date works for you.

Order Shipment

Within 1–2 business days from the time your item has shipped, you will receive an email confirmation with tracking information. If you have not received tracking information within 6 business days of your order, follow up with us at support@hearthdepot.com.

For LTL freight shipments, Free Shipping means Standard Curbside Delivery. Liftgate service is included on most freight shipments of large fireplaces and heaters.

Curbside delivery is defined as delivery of the freight as close to the actual delivery address as possible. Please remember that the size of the tractor trailer and certain safety precautions may prevent the freight carrier from delivering the freight at the actual curb or delivery address. For addresses located on a cul-de-sac, dead-end street, or dirt road, curbside delivery is not guaranteed; the customer may need to meet the driver at the nearest intersection or paved street that the delivery truck can access.

In special cases, when the customer's address is in a high-cost delivery area (e.g., remote areas or the center of a large city), an additional delivery fee may be required. To confirm the availability of the Free Shipping – Standard Curbside Delivery option for your address, please contact the HearthDepot team before placing your order.

If your order has been shipped within our standard time frame (or by a deadline agreed with you) and delivery is delayed due to the customer's fault, and the carrier requests storage fees for holding the shipment, or a redelivery attempt fee after a failed delivery attempt caused by the customer, HearthDepot may require the customer to cover these storage/redelivery fees for delivery to continue.

Customer Responsibility for Shipping Address Accuracy

It is the customer's responsibility to ensure that the shipping address entered at checkout is complete and accurate. We fulfill orders strictly based on the information provided during the purchase process.

Liability Waiver: We are not responsible for orders that are lost, delayed, or delivered to an incorrect destination due to an error in the shipping address provided by the customer, and we are not liable to provide refunds or complimentary replacements for items successfully delivered to an incorrect address originally provided by the customer at checkout.

Address Corrections: Address modifications can only be requested before the order has been processed or shipped. Once a tracking number is generated or the package is in transit, changes may not be possible, and carrier address-change fees may apply.

Returned Packages: If a package is returned to our warehouse due to an incorrect or incomplete address, the customer will be responsible for the cost of re-shipping the order to the corrected address.

Areas Covered

All estimated delivery dates and shipping costs advertised on the website apply to the contiguous (lower 48) United States. We also ship to Alaska, Hawaii, and Puerto Rico for the flat non-contiguous delivery fee shown at checkout (see Shipping Costs above); delivery to these areas typically takes 5–20 business days. We do not ship directly to Canada, but we can ship your order to a US freight forwarder of your choice.

Damages (items shipped via LTL freight)

It is very important that you inspect the packaging of your items when they arrive and check that you received all boxes listed on the delivery receipt.

If you notice any damage or a shortage of packages, you must note it on the bill of lading, take pictures, and refuse delivery of the damaged pieces. Your note should say "refused due to damage." You must also take photos of all sides of the box and send them to us within 24 hours. If no damage is visible before opening the box, note "subject to further inspection, may contain concealed damage" on the delivery receipt — do not sign "free and clear."

Before unpacking the item, take photos of the packaging from all sides even if there are no visible signs of damage — this is essential if concealed damage is discovered and a claim must be filed with the carrier or manufacturer. If you notice concealed damage after delivery, do not discard the packaging, and contact us with photos within 24 hours of delivery.

If you notice minor/cosmetic damage (e.g., a small scratch or dent) and would like to accept the item in this condition "as is," add a detailed description of the damage on the bill of lading before signing, and send us photos within 24 hours. We can then usually offer free touch-up options (where available) and/or a partial refund for the inconvenience; the granting and amount of a partial refund are not guaranteed, and an item accepted "as is" cannot subsequently be returned as damaged.

Important: accepting a visibly damaged shipment without any notation on the bill of lading severely limits our ability to file a carrier claim and may make a replacement or refund impossible. Always note damage before signing.

After we receive your report of refused delivery or concealed damage, we immediately initiate a claim with the shipping company or the manufacturer. Once the claim is processed, replacements ship at no cost to you.

Do not install the unit or connect it to gas or power until you have fully inspected it and confirmed it is free of damage. Once an appliance has been installed or operated, it can no longer be returned, and transit-damage claims become significantly harder to process.

Damages (items shipped as a parcel via FedEx / UPS / USPS)

Check the packaging upon receipt. If you notice any damage, photograph all sides of the box and send the photos to us within 24 hours. Before unpacking, photograph the packaging from all sides even if there is no visible damage. If the product inside is damaged, do not discard the original packaging — it will be needed for the claim procedure and any replacement shipment.

Returns

Looking to return an item? See our Returns & Refunds policy (linked in the footer) for the 45-day return window, conditions, and the RMA process.

Questions

Email: support@hearthdepot.com
Phone: +1 (888) 398-1887 (Monday–Saturday, 8:00 AM – 8:00 PM EST)
Mail: BE-COMMERCE LLC, 30 N Gould St Ste 24751, Sheridan, WY 82801, USA

At Hearth Depot, we’re committed to giving you the best deal online — guaranteed. If you find a lower price on an identical item, we’ll not only match it, but we’ll also beat it by 10% of the difference.

How It Works

1️⃣ Found a Lower Price?
If you discover a better price on the same item from another retailer (including shipping), just let us know.

2️⃣ We’ll Match or Beat It!
We’ll verify the competitor’s price and adjust your total to match it and reduce it by an additional 10% of the difference.

3️⃣ Applies Even After Purchase
Already purchased? No worries! If you find a lower price within 30 days of your purchase, we’ll refund the difference, including the 10% reduction.

Example Calculation

Let’s say:

  • The item price at Hearth Depot: $1,000
  • The item price on a competitor’s site: $950

Difference: $1,000 - $950 = $50
Your Savings: $50 x 10% = $5
Your New Total: $950 - $5 = $945

Limitations of the 110% Best Price Guarantee

Our guarantee ensures fairness and applies under the following conditions:

  • Promotions such as rebates, buy one get one free, or other special offers are not eligible.
  • The item must be identical — same brand, model number, size, finish, and configuration — new, and covered by the full manufacturer’s warranty.
  • The item must be in stock on the competitor’s website.
  • The competitor must be an online retailer (physical retail locations are excluded).
  • We do not match prices from online marketplaces, discounters or auction websites (e.g. Amazon, eBay, Overstock, etc.).
  • The competitor must be an Authorized Dealer of the product and must adhere to manufacturer pricing agreements, including minimum advertised price (MAP) policies.
  • The guarantee includes the item price and shipping costs, but excludes sales tax.
  • Certain brands may be excluded from the guarantee. Please contact us for details.

How to Claim

1️⃣ Contact us at support@hearthdepot.com or call +1 (888) 398-1887.
2️⃣ Provide the competitor’s link and details of the lower price.
3️⃣ We’ll verify and adjust your price or issue a refund for the difference.

Why Choose Hearth Depot?

✔ 110% Best Price Guarantee – Always get the best deal.
✔ Hassle-Free Shopping – Secure your order with confidence.
✔ 30-Day Price Protection – Covered even after you buy.
✔ Top Customer Service – We’re here to help Monday–Saturday, 8:00 AM – 8:00 PM EST.

The Empire Slope Glaze 18" Vent-Free Gas Burner is Empire's Slope Glaze vent-free burner in the 18" log length, for natural gas or propane. This one page covers the four controls Empire builds it with: Manual (VFSM, a manual valve with a hi / med / low knob), Millivolt (VFSR, a millivolt valve with an on/off switch), Variable Flame (VFSV, a standing pilot with the variable flame remote included) and Electronic Ignition (VFSE, intermittent pilot with thermostat remote).

It is a burner only: the log set is sold separately and chosen by the same log length. The burner installs in a solid-fuel burning masonry or UL 127 factory-built fireplace or in a listed ventless firebox, as a vent-free heater or, in a vented fireplace, as a vented decorative appliance.

You make two choices on this page: the control, in the Control Type selector, and the gas, in the Fuel Type selector. Each burner is built for one gas and is not convertible.

Which control is right for you?

The 18" Slope Glaze vent-free burner comes with four controls: Manual, Millivolt, Variable Flame and Electronic Ignition. Choose one in the Control Type selector above; the table shows what changes with each.

Manual Millivolt Variable Flame Electronic Ignition
Pilot and lighting Standing pilot, lit with the piezo igniter Standing pilot, lit with the piezo igniter Standing pilot, lit with the piezo igniter Intermittent pilot with electronic ignition
Turning the fire on and off At the control knob on the burner's valve On/off switch on the burner, once the pilot is lit From the included remote (ON/OFF key), with the receiver's slide switch set to REMOTE From the included remote, or at the burner's ON/OFF switch without the remote
Adjusting the flame Three settings on the control knob: high, medium, low At the burner: the valve carries a HI / LO regulator From the included remote: the H/L key steps through four levels (High, Medium High, Medium Low, Low). The gas flow knob can also be turned by hand From the included remote: flame height adjustable between high and low
Remote control None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional remote control can be wired in. The FRBTC2 is a battery thermostat remote (transmitter 2 x AAA, receiver 4 x AA); Empire lists it as an option for the millivolt VFSR burner. Thermostat mode is for vent-free installations only Included: variable flame remote. The receiver holds up to three transmitter codes, for a second handheld or a wall transmitter Included: a thermostatic remote control - on/off, flame height adjustable between high and low, and thermostat mode (vent-free installations only). The control module learns up to three transmitters, only one of them a thermostat type
Wall switch None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional wall switch can be wired in The receiver can also learn a wall transmitter Not stated by the manufacturer
Thermostat None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional thermostat can be wired in. Thermostats are for vent-free installations only Not stated by the manufacturer Included: the remote's THERMO mode cycles the burner on and off to hold the room temperature you set. Thermostat operation is for vent-free installations only; a vented installation needs the RCAF non-thermostat remote
Household power Not stated by the manufacturer The millivolt gas valve is powered by its thermopile and needs no household electricity. The optional FREC electric remote needs a 120 V receptacle The remote receiver runs on batteries and must not be connected to 110-120 V power Battery-powered control module (battery pack for 4 AA cells). An optional 7.5 V plug-in adapter, Empire part R10419, can be connected
Batteries Not stated by the manufacturer Not stated by the manufacturer Remote: one 12 V (A23) battery, included. Receiver: four AA, supplied; alkaline recommended. Battery life at least 12 months Control module: a battery pack, Energizer Lithium recommended for replacement. Fresh batteries are needed in the battery pack and in the remote before lighting
Maximum input 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr on natural gas, 30,000 BTU/hr on propane
Lowest setting 22,000 BTU/hr (natural gas or propane); medium setting 27,000 BTU/hr 22,000 BTU/hr (natural gas or propane) 21,000 BTU/hr (natural gas or propane) 19,000 BTU/hr on natural gas, 20,500 BTU/hr on propane
Minimum firebox front width 32 in 28 in 28 in 28 in
In the box, besides the burner Glowing embers and lava rock Glowing embers and lava rock Remote kit, glowing embers, lava rock, anchoring screws Remote kit, glowing embers, lava rock, anchoring screws
Gas and models VFSM18NAT (natural gas), VFSM18LP (propane). Built for one gas, not convertible VFSR18NAT (natural gas), VFSR18LP (propane). Built for one gas, not convertible VFSV18NAT (natural gas), VFSV18LP (propane). Built for one gas, not convertible VFSE18N (natural gas), VFSE18P (propane). Built for one gas, not convertible
In short Hand control at the burner with three heat settings; needs the widest firebox No remote in the box; an optional wall switch, thermostat or remote can be wired in Remote in the box for on/off and four flame levels Remote in the box that can hold a room temperature; lowest low setting of the four
  • If you want the fire to hold a room temperature with the remote that comes in the box, choose Electronic Ignition. Thermostat operation is for vent-free installations only.
  • If you want a remote in the box for on/off and four flame levels, choose Variable Flame.
  • If you want to wire in a wall switch, a thermostat or a remote of your own, choose Millivolt. None is included.
  • If you are happy to set the fire by hand at the burner, choose Manual and check the firebox first: it needs a front width of at least 32 in, where the other three need 28 in.

This burner also comes in 16", 24" and 30" - use the size selector above to compare.

Key Features

  • Four controls, one burner: Manual (VFSM), Millivolt (VFSR), Variable Flame (VFSV) or Electronic Ignition (VFSE) - the table in the Description tab compares them row by row.
  • Ratings: maximum input 30,000 to 32,000 BTU/hr; lowest setting 19,000 to 22,000 BTU/hr, by control and gas - each figure is in Specifications.
  • Add-on controls: Empire lists them for the Millivolt control. On Millivolt (VFSR) the thermopile-powered valve runs from its on/off switch and takes the FRBC / FRBTC2 / FREC remotes, the FWS1 wall switch, the TMV and TRW wall thermostats as options; the FREC electric remote needs a 120 V receptacle; thermostat-type controls - wall thermostats and thermostat remotes - are for vent-free installations only.
  • Vent-free and vented: complies with ANSI Z21.60 and CGA 2.26; vent-free in a fireplace or listed ventless firebox, vented decorative in a solid-fuel fireplace, where the damper clamp must be used, with the doors open and a screen in place.
  • Log set sold separately: any Slope Glaze log set of the 18" log length - the Williamsburg, Charleston, Ravenwood, Driftwood Burncrete, Stacked Wildwood, Super Stacked Wildwood, Saratoga, Charleston Select, Yorktown, Stacked Aged Oak, Sassafras, Super Sassafras, Ponderosa, Charred Oak, Super Charred Oak, Birch and Birch Burncrete sets are offered for this burner.
  • Listed accessories: the EK1 ember kit, PE20 platinum embers, the LR18 2-inch riser, the DCG24BL decorative grate, the GF24 flex gas line and the ELH1 adjustable hood. For Electronic Ignition (VFSE) Empire also lists the EK2 large ember kit.

Specifications

Models (Manual) VFSM18NAT (Natural Gas); VFSM18LP (Propane)
Models (Millivolt) VFSR18NAT (Natural Gas); VFSR18LP (Propane)
Models (Variable Flame) VFSV18NAT (Natural Gas); VFSV18LP (Propane)
Models (Electronic Ignition) VFSE18N (Natural Gas); VFSE18P (Propane)
Log length 18 in
Maximum input (Manual, Millivolt, Variable Flame) 32,000 BTU/hr
Maximum input (Electronic Ignition) 32,000 BTU/hr on natural gas, 30,000 BTU/hr on propane
Medium input (Manual) 27,000 BTU/hr
Minimum input (Manual, Millivolt) 22,000 BTU/hr
Minimum input (Variable Flame) 21,000 BTU/hr
Minimum input (Electronic Ignition) 19,000 BTU/hr on natural gas, 20,500 BTU/hr on propane
Control (Manual) Manual valve, standing pilot with piezo igniter, hi / med / low knob
Control (Millivolt) Millivolt valve, standing pilot with piezo igniter, on/off switch; remote or wall-switch ready
Control (Variable Flame) Variable flame valve, standing pilot with piezo igniter, variable remote (on/off, flame height) included
Control (Electronic Ignition) Intermittent pilot ignition; thermostatic remote control included: on/off, flame height adjustable between high and low, and thermostat mode (vent-free installations only)
Minimum firebox (Manual) Front width 32 in, rear width 21 in, depth 14 in, height 17 in
Minimum firebox (Millivolt, Variable Flame, Electronic Ignition) Front width 28 in, rear width 17 in, depth 14 in, height 17 in
Gas inlet 3/8 in NPT
Certification (Manual, Millivolt) ANSI Z21.60 / Z21.11, CGA 2.26; listed ventless fireboxes; mobile homes where codes allow
Certification (Variable Flame, Electronic Ignition) ANSI Z21.60, CGA 2.26; listed ventless fireboxes; mobile homes where codes allow
Shipping Weight (Manual) 20.2 lb (Natural Gas); 20.4 lb (Propane)
Shipping Weight (Millivolt) 21.4 lb (Natural Gas); 21.1 lb (Propane)
Shipping Weight (Variable Flame) 20.7 lb (Natural Gas); 24 lb (Propane)
Shipping Weight (Electronic Ignition) 21.7 lb (Natural Gas); 22.1 lb (Propane)

What's Included

  • Manual (VFSM): burner and grate assembly with manual valve, standing pilot (piezo) and hi / med / low knob; glowing embers (rock wool) and lava rock for the burner
  • Millivolt (VFSR): burner and grate assembly with millivolt valve, standing pilot (piezo) and on/off switch; glowing embers (rock wool) and lava rock for the burner
  • Variable Flame (VFSV): gas log grate and burner assembly; remote kit (variable remote); two masonry anchoring screws and two 10 x 1/2" black sheet metal anchoring screws; bag of glowing embers (rock wool) and a bag of lava rock
  • Electronic Ignition (VFSE): gas log grate and burner assembly; remote kit (thermostat variable remote); two masonry anchoring screws and two 10 x 1/2" black sheet metal anchoring screws; bag of glowing embers (rock wool) and a bag of lava rock
  • Not included with any control: the log set and the fireplace. Millivolt (VFSR) comes without a remote, switch or thermostat - those are add-on options.

Installation & Planning

How to choose your size

The size of a Slope Glaze burner is its log length. This is the 18" burner; it takes Slope Glaze log sets of the 18" log length. Check your firebox against the minimum dimensions below before you order.

Minimum firebox for the 18" burner Manual Millivolt, Variable Flame, Electronic Ignition
Firebox front width 32 in 28 in
Firebox rear width 21 in 17 in
Firebox depth 14 in 14 in
Firebox height 17 in 17 in
  • Reading the manual's drawing: the manual shows the minimum firebox as letters on its firebox figure. For Manual and Millivolt (Figure 5), U is the front width, W the rear width, V the depth and T the height. For Variable Flame and Electronic Ignition (Figure 2), C is the front width, A the rear width, B the depth and D the height.
  • Glass doors: on a fireplace with glass doors, the door-frame opening is the minimum front opening of the firebox.
  • If your firebox is smaller: this burner comes in other sizes - use the size selector above to compare them.
  • Log set required: this burner requires a Slope Glaze log set of the 18" log length - choose one in the Log Set selector on this page, which lists the 17 sets offered for this burner size.
  • Where it goes: a solid-fuel burning masonry or UL 127 factory-built fireplace, cleaned of creosote first, or a listed ventless firebox; in a vented installation the damper clamp must be used, the glass doors stay open and a screen is in place; in a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first time.
  • Clearances: the sides of the fireplace opening 6" from any combustible wall; the ceiling at least 41" above the opening; without a hood, non-combustible material at least 12" above the opening (slate or marble at least 1/2" thick).
  • Vent-free room rules: supplemental zone heat for a room with enough combustion and ventilation air; an unvented heater over 10,000 BTU/hr may not be installed in a bedroom and one over 6,000 BTU/hr may not be installed in a bathroom; an unvented heater adds about an ounce of water vapor per 1,000 BTU of input each hour; some state and local codes prohibit unvented heaters - check yours first.
  • Gas: the burner is built for natural gas or propane and is not convertible - order the variant for your gas; installation, piping and service by a qualified agency (Massachusetts: licensed plumber or gas fitter).
  • Controls and thermostats: on Millivolt (VFSR), thermostat-type controls - a wall thermostat or a thermostat remote - are for vent-free installations only; a wall switch or a non-thermostat remote is optional in either installation. On Electronic Ignition (VFSE), a vented installation must use the separate RCAF non-thermostat remote, because the included thermostatic remote is for vent-free use.
  • Handle by the grate (Variable Flame, Electronic Ignition): the assembly is carried by the grate and legs, never by the burner; the glowing embers go on the front of the burner only.
  • Documents: two manuals are listed in the Documents section below, and each covers different controls: the one labelled Installation Manual (Empire 27829) is the installation and owner's manual for Manual (VFSM) and Millivolt (VFSR); the one labelled Owner's Manual (Empire 47343) is the installation and owner's manual for Variable Flame (VFSV) and Electronic Ignition (VFSE). Each carries the ratings, firebox dimensions, clearances, damper clamp and lighting instructions for the controls it covers. The vent-free burners brochure is there as well; each log set carries its own placement manual.

Warranty

  • 5 years: parts and labor on the burner's components
  • 1 year: parts on remote controls, thermostats, accessories and replacement parts

Empire's limited warranty is for the original purchaser and calls for installation by a qualified installer.

The Empire Slope Glaze 18" Vent-Free Gas Burner is Empire's Slope Glaze vent-free burner in the 18" log length, for natural gas or propane. This one page covers the four controls Empire builds it with: Manual (VFSM, a manual valve with a hi / med / low knob), Millivolt (VFSR, a millivolt valve with an on/off switch), Variable Flame (VFSV, a standing pilot with the variable flame remote included) and Electronic Ignition (VFSE, intermittent pilot with thermostat remote).

It is a burner only: the log set is sold separately and chosen by the same log length. The burner installs in a solid-fuel burning masonry or UL 127 factory-built fireplace or in a listed ventless firebox, as a vent-free heater or, in a vented fireplace, as a vented decorative appliance.

You make two choices on this page: the control, in the Control Type selector, and the gas, in the Fuel Type selector. Each burner is built for one gas and is not convertible.

Which control is right for you?

The 18" Slope Glaze vent-free burner comes with four controls: Manual, Millivolt, Variable Flame and Electronic Ignition. Choose one in the Control Type selector above; the table shows what changes with each.

Manual Millivolt Variable Flame Electronic Ignition
Pilot and lighting Standing pilot, lit with the piezo igniter Standing pilot, lit with the piezo igniter Standing pilot, lit with the piezo igniter Intermittent pilot with electronic ignition
Turning the fire on and off At the control knob on the burner's valve On/off switch on the burner, once the pilot is lit From the included remote (ON/OFF key), with the receiver's slide switch set to REMOTE From the included remote, or at the burner's ON/OFF switch without the remote
Adjusting the flame Three settings on the control knob: high, medium, low At the burner: the valve carries a HI / LO regulator From the included remote: the H/L key steps through four levels (High, Medium High, Medium Low, Low). The gas flow knob can also be turned by hand From the included remote: flame height adjustable between high and low
Remote control None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional remote control can be wired in. The FRBTC2 is a battery thermostat remote (transmitter 2 x AAA, receiver 4 x AA); Empire lists it as an option for the millivolt VFSR burner. Thermostat mode is for vent-free installations only Included: variable flame remote. The receiver holds up to three transmitter codes, for a second handheld or a wall transmitter Included: a thermostatic remote control - on/off, flame height adjustable between high and low, and thermostat mode (vent-free installations only). The control module learns up to three transmitters, only one of them a thermostat type
Wall switch None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional wall switch can be wired in The receiver can also learn a wall transmitter Not stated by the manufacturer
Thermostat None listed for Manual: the manual for the Manual (VFSM) and Millivolt (VFSR) burners marks its optional controls for use with VFSR models only Not included. An optional thermostat can be wired in. Thermostats are for vent-free installations only Not stated by the manufacturer Included: the remote's THERMO mode cycles the burner on and off to hold the room temperature you set. Thermostat operation is for vent-free installations only; a vented installation needs the RCAF non-thermostat remote
Household power Not stated by the manufacturer The millivolt gas valve is powered by its thermopile and needs no household electricity. The optional FREC electric remote needs a 120 V receptacle The remote receiver runs on batteries and must not be connected to 110-120 V power Battery-powered control module (battery pack for 4 AA cells). An optional 7.5 V plug-in adapter, Empire part R10419, can be connected
Batteries Not stated by the manufacturer Not stated by the manufacturer Remote: one 12 V (A23) battery, included. Receiver: four AA, supplied; alkaline recommended. Battery life at least 12 months Control module: a battery pack, Energizer Lithium recommended for replacement. Fresh batteries are needed in the battery pack and in the remote before lighting
Maximum input 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr (natural gas or propane) 32,000 BTU/hr on natural gas, 30,000 BTU/hr on propane
Lowest setting 22,000 BTU/hr (natural gas or propane); medium setting 27,000 BTU/hr 22,000 BTU/hr (natural gas or propane) 21,000 BTU/hr (natural gas or propane) 19,000 BTU/hr on natural gas, 20,500 BTU/hr on propane
Minimum firebox front width 32 in 28 in 28 in 28 in
In the box, besides the burner Glowing embers and lava rock Glowing embers and lava rock Remote kit, glowing embers, lava rock, anchoring screws Remote kit, glowing embers, lava rock, anchoring screws
Gas and models VFSM18NAT (natural gas), VFSM18LP (propane). Built for one gas, not convertible VFSR18NAT (natural gas), VFSR18LP (propane). Built for one gas, not convertible VFSV18NAT (natural gas), VFSV18LP (propane). Built for one gas, not convertible VFSE18N (natural gas), VFSE18P (propane). Built for one gas, not convertible
In short Hand control at the burner with three heat settings; needs the widest firebox No remote in the box; an optional wall switch, thermostat or remote can be wired in Remote in the box for on/off and four flame levels Remote in the box that can hold a room temperature; lowest low setting of the four
  • If you want the fire to hold a room temperature with the remote that comes in the box, choose Electronic Ignition. Thermostat operation is for vent-free installations only.
  • If you want a remote in the box for on/off and four flame levels, choose Variable Flame.
  • If you want to wire in a wall switch, a thermostat or a remote of your own, choose Millivolt. None is included.
  • If you are happy to set the fire by hand at the burner, choose Manual and check the firebox first: it needs a front width of at least 32 in, where the other three need 28 in.

This burner also comes in 16", 24" and 30" - use the size selector above to compare.

Key Features

  • Four controls, one burner: Manual (VFSM), Millivolt (VFSR), Variable Flame (VFSV) or Electronic Ignition (VFSE) - the table in the Description tab compares them row by row.
  • Ratings: maximum input 30,000 to 32,000 BTU/hr; lowest setting 19,000 to 22,000 BTU/hr, by control and gas - each figure is in Specifications.
  • Add-on controls: Empire lists them for the Millivolt control. On Millivolt (VFSR) the thermopile-powered valve runs from its on/off switch and takes the FRBC / FRBTC2 / FREC remotes, the FWS1 wall switch, the TMV and TRW wall thermostats as options; the FREC electric remote needs a 120 V receptacle; thermostat-type controls - wall thermostats and thermostat remotes - are for vent-free installations only.
  • Vent-free and vented: complies with ANSI Z21.60 and CGA 2.26; vent-free in a fireplace or listed ventless firebox, vented decorative in a solid-fuel fireplace, where the damper clamp must be used, with the doors open and a screen in place.
  • Log set sold separately: any Slope Glaze log set of the 18" log length - the Williamsburg, Charleston, Ravenwood, Driftwood Burncrete, Stacked Wildwood, Super Stacked Wildwood, Saratoga, Charleston Select, Yorktown, Stacked Aged Oak, Sassafras, Super Sassafras, Ponderosa, Charred Oak, Super Charred Oak, Birch and Birch Burncrete sets are offered for this burner.
  • Listed accessories: the EK1 ember kit, PE20 platinum embers, the LR18 2-inch riser, the DCG24BL decorative grate, the GF24 flex gas line and the ELH1 adjustable hood. For Electronic Ignition (VFSE) Empire also lists the EK2 large ember kit.

Specifications

Models (Manual) VFSM18NAT (Natural Gas); VFSM18LP (Propane)
Models (Millivolt) VFSR18NAT (Natural Gas); VFSR18LP (Propane)
Models (Variable Flame) VFSV18NAT (Natural Gas); VFSV18LP (Propane)
Models (Electronic Ignition) VFSE18N (Natural Gas); VFSE18P (Propane)
Log length 18 in
Maximum input (Manual, Millivolt, Variable Flame) 32,000 BTU/hr
Maximum input (Electronic Ignition) 32,000 BTU/hr on natural gas, 30,000 BTU/hr on propane
Medium input (Manual) 27,000 BTU/hr
Minimum input (Manual, Millivolt) 22,000 BTU/hr
Minimum input (Variable Flame) 21,000 BTU/hr
Minimum input (Electronic Ignition) 19,000 BTU/hr on natural gas, 20,500 BTU/hr on propane
Control (Manual) Manual valve, standing pilot with piezo igniter, hi / med / low knob
Control (Millivolt) Millivolt valve, standing pilot with piezo igniter, on/off switch; remote or wall-switch ready
Control (Variable Flame) Variable flame valve, standing pilot with piezo igniter, variable remote (on/off, flame height) included
Control (Electronic Ignition) Intermittent pilot ignition; thermostatic remote control included: on/off, flame height adjustable between high and low, and thermostat mode (vent-free installations only)
Minimum firebox (Manual) Front width 32 in, rear width 21 in, depth 14 in, height 17 in
Minimum firebox (Millivolt, Variable Flame, Electronic Ignition) Front width 28 in, rear width 17 in, depth 14 in, height 17 in
Gas inlet 3/8 in NPT
Certification (Manual, Millivolt) ANSI Z21.60 / Z21.11, CGA 2.26; listed ventless fireboxes; mobile homes where codes allow
Certification (Variable Flame, Electronic Ignition) ANSI Z21.60, CGA 2.26; listed ventless fireboxes; mobile homes where codes allow
Shipping Weight (Manual) 20.2 lb (Natural Gas); 20.4 lb (Propane)
Shipping Weight (Millivolt) 21.4 lb (Natural Gas); 21.1 lb (Propane)
Shipping Weight (Variable Flame) 20.7 lb (Natural Gas); 24 lb (Propane)
Shipping Weight (Electronic Ignition) 21.7 lb (Natural Gas); 22.1 lb (Propane)

What's Included

  • Manual (VFSM): burner and grate assembly with manual valve, standing pilot (piezo) and hi / med / low knob; glowing embers (rock wool) and lava rock for the burner
  • Millivolt (VFSR): burner and grate assembly with millivolt valve, standing pilot (piezo) and on/off switch; glowing embers (rock wool) and lava rock for the burner
  • Variable Flame (VFSV): gas log grate and burner assembly; remote kit (variable remote); two masonry anchoring screws and two 10 x 1/2" black sheet metal anchoring screws; bag of glowing embers (rock wool) and a bag of lava rock
  • Electronic Ignition (VFSE): gas log grate and burner assembly; remote kit (thermostat variable remote); two masonry anchoring screws and two 10 x 1/2" black sheet metal anchoring screws; bag of glowing embers (rock wool) and a bag of lava rock
  • Not included with any control: the log set and the fireplace. Millivolt (VFSR) comes without a remote, switch or thermostat - those are add-on options.

Installation & Planning

How to choose your size

The size of a Slope Glaze burner is its log length. This is the 18" burner; it takes Slope Glaze log sets of the 18" log length. Check your firebox against the minimum dimensions below before you order.

Minimum firebox for the 18" burner Manual Millivolt, Variable Flame, Electronic Ignition
Firebox front width 32 in 28 in
Firebox rear width 21 in 17 in
Firebox depth 14 in 14 in
Firebox height 17 in 17 in
  • Reading the manual's drawing: the manual shows the minimum firebox as letters on its firebox figure. For Manual and Millivolt (Figure 5), U is the front width, W the rear width, V the depth and T the height. For Variable Flame and Electronic Ignition (Figure 2), C is the front width, A the rear width, B the depth and D the height.
  • Glass doors: on a fireplace with glass doors, the door-frame opening is the minimum front opening of the firebox.
  • If your firebox is smaller: this burner comes in other sizes - use the size selector above to compare them.
  • Log set required: this burner requires a Slope Glaze log set of the 18" log length - choose one in the Log Set selector on this page, which lists the 17 sets offered for this burner size.
  • Where it goes: a solid-fuel burning masonry or UL 127 factory-built fireplace, cleaned of creosote first, or a listed ventless firebox; in a vented installation the damper clamp must be used, the glass doors stay open and a screen is in place; in a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first time.
  • Clearances: the sides of the fireplace opening 6" from any combustible wall; the ceiling at least 41" above the opening; without a hood, non-combustible material at least 12" above the opening (slate or marble at least 1/2" thick).
  • Vent-free room rules: supplemental zone heat for a room with enough combustion and ventilation air; an unvented heater over 10,000 BTU/hr may not be installed in a bedroom and one over 6,000 BTU/hr may not be installed in a bathroom; an unvented heater adds about an ounce of water vapor per 1,000 BTU of input each hour; some state and local codes prohibit unvented heaters - check yours first.
  • Gas: the burner is built for natural gas or propane and is not convertible - order the variant for your gas; installation, piping and service by a qualified agency (Massachusetts: licensed plumber or gas fitter).
  • Controls and thermostats: on Millivolt (VFSR), thermostat-type controls - a wall thermostat or a thermostat remote - are for vent-free installations only; a wall switch or a non-thermostat remote is optional in either installation. On Electronic Ignition (VFSE), a vented installation must use the separate RCAF non-thermostat remote, because the included thermostatic remote is for vent-free use.
  • Handle by the grate (Variable Flame, Electronic Ignition): the assembly is carried by the grate and legs, never by the burner; the glowing embers go on the front of the burner only.
  • Documents: two manuals are listed in the Documents section below, and each covers different controls: the one labelled Installation Manual (Empire 27829) is the installation and owner's manual for Manual (VFSM) and Millivolt (VFSR); the one labelled Owner's Manual (Empire 47343) is the installation and owner's manual for Variable Flame (VFSV) and Electronic Ignition (VFSE). Each carries the ratings, firebox dimensions, clearances, damper clamp and lighting instructions for the controls it covers. The vent-free burners brochure is there as well; each log set carries its own placement manual.

Warranty

  • 5 years: parts and labor on the burner's components
  • 1 year: parts on remote controls, thermostats, accessories and replacement parts

Empire's limited warranty is for the original purchaser and calls for installation by a qualified installer.

Get in touch with us

Get in touch with us

Text or Call : 888-398-1887or simply start a live chat with our experts.

Average response time is 39 seconds. We are ready to help: Monday - Saturday; 8:00 AM - 8:00 PM EST

support@hearthdepot.com

Text or Call : 888-398-1887or simply start a live chat with our experts.

Average response time is 39 seconds. We are ready to help: Monday - Saturday; 8:00 AM - 8:00 PM EST

support@hearthdepot.com

Top reasons to buy from us

Top reasons to buy from us

Free Shipping

On orders over $200 (contiguous US)

Best Warranty Available

Full manufacturer warranty on every product

Lowest Price Online

110% Best Price Guarantee: find it lower, we beat it

Safe & Secure Ordering

PCI-compliant, SSL-encrypted checkout

★★★★★
★★★★★
★★★★★
★★★★★

Search

Call 888-398-1887Mon–Sat 8am–8pm ET
>